Move all files one level up in the file hierarcy, to avoid the useless ipmitool directory.

This commit is contained in:
Petter Reinholdtsen
2014-02-05 17:30:32 +01:00
parent b0aad15d67
commit c18ec02f33
171 changed files with 0 additions and 0 deletions

41
contrib/Makefile.am Normal file
View File

@@ -0,0 +1,41 @@
# Copyright (c) 2003 Sun Microsystems, Inc. All Rights Reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions
# are met:
#
# Redistribution of source code must retain the above copyright
# notice, this list of conditions and the following disclaimer.
#
# Redistribution in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
#
# Neither the name of Sun Microsystems, Inc. or the names of
# contributors may be used to endorse or promote products derived
# from this software without specific prior written permission.
#
# This software is provided "AS IS," without a warranty of any kind.
# ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
# INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A
# PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE HEREBY EXCLUDED.
# SUN MICROSYSTEMS, INC. ("SUN") AND ITS LICENSORS SHALL NOT BE LIABLE
# FOR ANY DAMAGES SUFFERED BY LICENSEE AS A RESULT OF USING, MODIFYING
# OR DISTRIBUTING THIS SOFTWARE OR ITS DERIVATIVES. IN NO EVENT WILL
# SUN OR ITS LICENSORS BE LIABLE FOR ANY LOST REVENUE, PROFIT OR DATA,
# OR FOR DIRECT, INDIRECT, SPECIAL, CONSEQUENTIAL, INCIDENTAL OR
# PUNITIVE DAMAGES, HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF
# LIABILITY, ARISING OUT OF THE USE OF OR INABILITY TO USE THIS SOFTWARE,
# EVEN IF SUN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
MAINTAINERCLEANFILES = Makefile.in
dist_pkgdata_DATA = oem_ibm_sel_map
EXTRA_DIST = README \
bmclanconf ipmi.init.basic ipmi.init.redhat \
exchange-bmc-os-info.init.redhat exchange-bmc-os-info.service.redhat \
exchange-bmc-os-info.sysconf \
ipmievd.init.redhat ipmievd.init.suse ipmievd.init.debian \
collect_data.sh create_rrds.sh create_webpage_compact.sh create_webpage.sh \
bmc-snmp-proxy bmc-snmp-proxy.service bmc-snmp-proxy.sysconf

95
contrib/README Normal file
View File

@@ -0,0 +1,95 @@
Graphs for ipmitool
-------------------
This is a set of shell-scripts to quickly create a webpage with pretty graphs!
Prerequisites are a webserver with cgi-bin support and RRDtool, a data
collection and graphing utility you can get here:
http://people.ee.ethz.ch/~oetiker/webtools/rrdtool/
First, decide on a directory where to store the RRDtool database files and make
sure it exists. The user that will run the cronjob to collect updates must have
write permissions in this dir.
Next, you'll need to edit some variables at the top of each script.
Common to all scripts:
hostname Override this if you are collecting data from a remote host,
or if the $HOSTNAME variable is incorrect.
ipmi_cmd Command line used to call ipmitool. Default is to collect
data from the local server using OpenIPMI.
If you want to collect data from a remote host, add the
-I lan, -H, -U and -P options as necessary.
BIG NOTE! I do not recommend using remote data collection since
you'll have to store the password in the script. If you do,
make sure unauthorized people can't read or execute the scripts
or they'll be able to wreak havoc on your server.
rrd_dir Enter the dir where to store the RRDtool database here.
Now you can get the data collection going. Run create_rrds.sh to create the
RDDtool database, you'll find one .rrd file per sensor in the designated dir.
Add a line to your crontab that executes collect_data.sh every 5 minutes.
Something like this:
*/5 * * * * /usr/local/bin/collect_data.sh
If you are a Solaris user you'll have to write the more verbose:
0,5,10,15,20,25,30,35,40,45,50,55 * * * * /usr/local/bin/collect_data.sh
Finally it's time to create the webpage, begin with editing some more variables
in the create_webpage.sh and/or create_webpage_compact.sh scripts:
rrdcgi Full path to the rrdcgi executable.
img_dir Directory to store the graph images. This path must be within
the document root and writable by the web server user.
Example: /usr/local/apache2/htdocs/images/graphs
web_dir Relative path of the URL where the images will show up
on the web server.
Example: With the img_dir path above the corresponding web_dir
would be /images/graphs
graph_width Size of the graph area in pixels (excluding title, legends etc.)
graph_height
graph_daily Decide which of daily, weekly and monthly graphs you want
graph_weekly included on the page.
graph_monthly
Finally run the create webpage script and store the output as a cgi-script and
don't forget to make it executable.
Example:
create_webpage.sh > /usr/local/apache2/cgi-bin/my_ipmi_graphs.cgi
chmod 755 /usr/local/apache2/cgi-bin/my_ipmi_graphs.cgi
Now you can surf to http://my.server.com/cgi-bin/my_ipmi_graphs.cgi and enjoy!
The difference between create_webpage.sh and create_webpage_compact.sh is that
the first script displays sensor thresholds in the graphs. The second script
collects all sensors that measure the same unit into the same graph thus
producing a lot fewer graphs.
Note, RRDtool sometimes scales the graphs such that the sensor thresholds
fall outside the visible area.
Happy graphing!

381
contrib/bmc-snmp-proxy Normal file
View File

@@ -0,0 +1,381 @@
#!/bin/sh
#############################################################################
#
# bmc-snmp-proxy: Set SNMP proxy to BMC (Baseboard Management Controller)
#
# version: 0.6
#
# Authors: Charles Rose <charles_rose@dell.com>
# Jordan Hargrave <jordan_hargrave@dell.com>
#
# Description: Script to set snmp proxy to the BMC for certain OID
# See here for details:
# https://fedoraproject.org/wiki/Features/AgentFreeManagement
#
# Assumptions: This script will work only when /etc/snmp/ is writable.
#
#############################################################################
# GLOBALS
#############################################################################
SYSCONF_DIR="/etc/sysconfig"
CONFIG="${SYSCONF_DIR}/bmc-snmp-proxy"
SNMPD_LOCAL_CONF_DIR="/etc/snmp/bmc"
SNMPD_LOCAL_CONF="${SNMPD_LOCAL_CONF_DIR}/snmpd.local.conf"
TRAPD_LOCAL_CONF="${SNMPD_LOCAL_CONF_DIR}/snmptrapd.local.conf"
TRAPD_CONF="/etc/snmp/snmptrapd.conf"
LOCKFILE="/var/lock/subsys/bmc-snmp-proxy"
BMC_INFO="/var/run/bmc-info"
IPMITOOL=`which ipmitool`
#Default config
BMC_COMMUNITY="public"
BMC_OID=".1.3.6.1.4.1.674.10892.2" # Dell iDRAC
TRAP_FORWARD="no"
RELOAD_SERVICES="yes"
#############################################################################
#TODO: Use inotify and daemonize when $BMC_INFO changes
# source config
[ -r ${CONFIG} ] && . ${CONFIG}
. gettext.sh
SCRIPT_NAME=$(basename $0)
RETVAL=0
# Check if bmc-info created by exchange-bmc-os-info
bmc_info_exists()
{
if [ -r "${BMC_INFO}" ]; then
. ${BMC_INFO}
else
RETVAL=2
fi
return $RETVAL
}
check_snmp()
{
if [ ! -d /etc/snmp ] && [ ! -x /usr/sbin/snmpd ]; then
RETVAL=12
fi
return $RETVAL
}
#############################################################################
# configure SNMP proxy
#############################################################################
write_snmp_conf()
{
# SNMPv3 security: bmcview, bmc_ctx, bmc_sec, bmc_grp, bmc_cmty
printf "###############################################\n"
printf "# Automatically created by %s #\n" "${SCRIPT_NAME}"
printf "###############################################\n"
printf "view bmcview included %s 80\n" "${BMC_OID}"
printf "com2sec -Cn bmc_ctx bmc_sec default bmc_cmty\n"
printf "group bmc_grp v1 bmc_sec\n"
printf "access bmc_grp bmc_ctx any noauth exact bmcview none none\n"
printf "proxy -Cn bmc_ctx -v 1 %s\n" "${PROXY_TOKEN}"
printf "###############################################\n"
}
valid_ip()
{
#Thanks to mkyong.com
octet="([01]?[[:digit:]][[:digit:]]?|2[0-4][[:digit:]]|25[0-5])"
printf -- "%s" "${1}"| grep -Eq \
"^${octet}\\.${octet}\\.${octet}\\.${octet}$"
return $?
}
check_vars()
{
[ -z ${BMC_COMMUNITY} ] && BMC_COMMUNITY="public"
[ -z ${BMC_OID} ] && return 1
if [ -n "${BMC_IPv4}" ] && valid_ip ${BMC_IPv4}; then
return 0
else
return 1
fi
}
set_snmp_proxy()
{
if check_vars; then
PROXY_TOKEN="-c ${BMC_COMMUNITY} ${BMC_IPv4} ${BMC_OID}"
if [ ! -d ${SNMPD_LOCAL_CONF_DIR} ] && \
mkdir ${SNMPD_LOCAL_CONF_DIR}; then
write_snmp_conf > ${SNMPD_LOCAL_CONF}
[ $? -ne 0 ] && RETVAL=4
fi
else
RETVAL=3
fi
}
set_snmpd_conf_path()
{
for SYSCONF in ${SYSCONF_DIR}/snmp*d;
do
if grep -q "${SNMPD_LOCAL_CONF_DIR}" "${SYSCONF}" > \
/dev/null 2>&1; then
continue
else
printf "SNMPCONFPATH=%s\n" "${SNMPD_LOCAL_CONF_DIR}" \
>> ${SYSCONF} || RETVAL=7
fi
done
return $RETVAL
}
disable_snmp_proxy()
{
if [ -f ${SNMPD_LOCAL_CONF} ]; then
rm -f ${SNMPD_LOCAL_CONF}
[ $? -ne 0 ] && RETVAL=5
fi
}
#############################################################################
# Trap Forwarding
#############################################################################
pick_alert_dest()
{
test_ip="$1"
for ALERT_DEST in `seq 1 4`
do
temp_ip=$(${IPMITOOL} lan alert print ${CHANNEL} ${ALERT_DEST}\
2>/dev/null| sed -n "s#^Alert IP Address.*: ##p")
[ "${temp_ip}" = "${test_ip}" ] && return 0
done
return 1
}
set_alert_dest_ip()
{
${IPMITOOL} lan alert set ${CHANNEL} ${ALERT_DEST} ipaddr ${1} \
retry 4 type pet >/dev/null 2>&1
[ $? -ne 0 ] && RETVAL=8
}
bmc_alert_dest()
{
# Pick the first active LAN channel
for CHANNEL in `seq 1 14`
do
[ $(${IPMITOOL} -I open channel info ${CHANNEL} 2>/dev/null \
| grep -q "802\.3") ] || break
done
# If TRAPD_IP is already set as an alert dest,
if pick_alert_dest "${TRAPD_IP}"; then
# reset: reset it if we are called with reset
[ "${1}" = "reset" ] && \
set_alert_dest_ip "0.0.0.0"
# else, find the next free alert dest,
elif pick_alert_dest "0.0.0.0"; then
[ "${1}" = "reset" ] && \
return $RETVAL
# set: the TRAPD_IP
set_alert_dest_ip "${TRAPD_IP}"
else
# No free alert destinations
RETVAL=9
fi
return $RETVAL
}
set_ipmi_alert()
{
${IPMITOOL} lan set ${CHANNEL} alert "${1}" >/dev/null 2>&1
[ $? -ne 0 ] && RETVAL=10
}
get_host_ip()
{
# Get host's IP that the BMC can reach.
IFACE=$(/usr/sbin/ip -o -f inet address |awk '!/: lo/ {print $2}')
for dev in ${IFACE}
do
ping -c 1 -I ${dev} ${BMC_IPv4} > /dev/null 2>&1
done
}
config_bmc_alert()
{
# Get Host's IP that the BMC can send traps to
TRAPD_IP=$(get_host_ip)
# Set Host's IP as the alert destination in the BMC
valid_ip ${TRAPD_IP} && bmc_alert_dest "${ACTION}"
# Enable alerting on the LAN channel
[ $RETVAL -eq 0 ] && set_ipmi_alert "${ACTION}"
}
write_trapd_conf()
{
printf "###############################################\n"
printf "# Automatically created by %s #\n" "${SCRIPT_NAME}"
printf "forward %s %s\n" "${BMC_OID}*" "${FORWARD_HOST}"
printf "###############################################\n"
}
config_trapd()
{
# Proceed only if snmptrapd is available on the system
if [ -f ${TRAPD_CONF} ]; then
write_trapd_conf > ${TRAPD_LOCAL_CONF}
[ $? -ne 0 ] && RETVAL=11
else
return 1
fi
}
trap_sink_exists()
{
# TODO: We only set the first match. We should be able to set
# multiple
FORWARD_HOST=$(awk '/^trap.*sink/{print $2}; /^informsink/{print $2}' \
/etc/snmp/snmpd*conf | head -1)
if [ -z "${FORWARD_HOST}" ]; then
# there is no trapsink setup.
return 1
else
return 0
fi
}
# Forward SNMP traps from the BMC to trapsink.
trap_forward()
{
NO_TRAP=0
ACTION=${1} # set or reset
if [ "${ACTION}" = "set" ]; then
# Get trapd config,
if trap_sink_exists; then
config_trapd && config_bmc_alert
else
# exit silently if there is no sink
NO_TRAP=1
fi
else
if [ -f ${TRAPD_LOCAL_CONF} ]; then
rm -f ${TRAPD_LOCAL_CONF} >/dev/null 2>&1
else
NO_TRAP=1
fi
fi
}
#############################################################################
service_reload()
{
#TODO: do this in systemd
if [ ${RETVAL} -eq 0 ] && [ "${RELOAD_SERVICES}" = "yes" ]; then
service $1 reload
[ $? -ne 0 ] && RETVAL=6
fi
return
}
#############################################################################
start()
{
if bmc_info_exists && check_snmp; then
touch ${LOCKFILE}
set_snmpd_conf_path && set_snmp_proxy
[ $RETVAL -eq 0 ] && service_reload snmpd
if [ "${TRAP_FORWARD}" = "yes" ]; then
trap_forward "set"
[ $RETVAL -eq 0 ] && [ $NO_TRAP -eq 0 ] && \
service_reload snmptrapd
fi
fi
}
#############################################################################
stop()
{
[ ! -f ${LOCKFILE} ] && return
if bmc_info_exists && check_snmp; then
disable_snmp_proxy
[ $RETVAL -eq 0 ] && service_reload snmpd
if [ "${TRAP_FORWARD}" = "yes" ]; then
trap_forward "reset"
[ $RETVAL -eq 0 ] && [ $NO_TRAP -eq 0 ] && \
service_reload snmptrapd
fi
rm -f ${LOCKFILE}
fi
}
#############################################################################
status()
{
eval_gettext "${SCRIPT_NAME}: snmp proxy to BMC is "
# Checking for lockfile is better.
#if grep -q "^proxy" "${SNMPD_LOCAL_CONF}" > /dev/null 2>&1 ; then
if [ -f ${LOCKFILE} ]; then
eval_gettext "set"
else
eval_gettext "not set"
fi
echo
RETVAL=0
}
#############################################################################
usage()
{
eval_gettext "Usage: $0 {start|stop|status}"; echo 1>&2
RETVAL=1
}
#############################################################################
# MAIN
#############################################################################
case "$1" in
start) start ;;
stop) stop ;;
status) status ;;
*) usage ;;
esac
case "$RETVAL" in
0|1) ;;
2) eval_gettext "${SCRIPT_NAME}: failed to read ${BMC_INFO} " 1>&2 ;;
3) eval_gettext "${SCRIPT_NAME}: failed to get proxy config." 1>&2 ;;
4) eval_gettext "${SCRIPT_NAME}: failed to set ${SNMPD_LOCAL_CONF}." 1>&2 ;;
5) eval_gettext "${SCRIPT_NAME}: failed to disable snmp proxy." 1>&2 ;;
6) eval_gettext "${SCRIPT_NAME}: failed to reload snmpd." 1>&2 ;;
7) eval_gettext "${SCRIPT_NAME}: failed to update ${SYSCONF}." 1>&2 ;;
8) eval_gettext "${SCRIPT_NAME}: failed to set IPMI alert dest." 1>&2 ;;
9) eval_gettext "${SCRIPT_NAME}: no free IPMI alert dest." 1>&2 ;;
10) eval_gettext "${SCRIPT_NAME}: failed to set IPMI PEF." 1>&2 ;;
11) eval_gettext "${SCRIPT_NAME}: failed to write snmptrapd.conf." 1>&2 ;;
12) eval_gettext "${SCRIPT_NAME}: snmpd not found." 1>&2 ;;
*) eval_gettext "${SCRIPT_NAME}: unknown error." 1>&2 ;;
esac
if [ ${RETVAL} -gt 1 ]; then
eval_gettext " Return code: ${RETVAL}"; echo
fi
exit ${RETVAL}
#############################################################################
# end of file
#############################################################################

View File

@@ -0,0 +1,18 @@
[Unit]
Description=Setup SNMP proxy to BMC
After=exchange-bmc-os-info.service
Requires=exchange-bmc-os-info.service
PartOf=exchange-bmc-os-info.service
ConditionPathExists=/var/run/bmc-info
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/libexec/bmc-snmp-proxy start
ExecStop=/usr/libexec/bmc-snmp-proxy stop
[Install]
WantedBy=multi-user.target

View File

@@ -0,0 +1,48 @@
# bmc-snmp-proxy
#
# Config file to control SNMP redirection between
# the OS and Service Processor/Baseboard Management Controller (BMC)
#
# bmc-snnmp-proxy helps redirect certain SNMP requests (to this host)
# destined to the Service Processor. We will need the Service Processor's
# SNMP community string and the OID of the Service Processor's SNMP agent.
#
# For redirecting Traps from the Service Processor to the trap sink
# configured in the host (this system), we will have to set
# TRAP_FORWARD below.
#
# See here for details
# https://fedoraproject.org/wiki/Features/AgentFreeManagement
### Configure SNMP proxy to BMC/Service Processor ###
### Service Processor/BMC SNMP Community String.
# Name: BMC_COMMUNITY
# Description: Set community string of the Service Processor (BMC)'s
# SNMP agent.
# Default: public
#
BMC_COMMUNITY="public"
### OEM Specific OID of Service Processor
# Name: BMC_OID
# Description: SNMP OID that we would like to redirect to the Service
# Processor (BMC). This can be unique to each OEM.
# Default: ".1.3.6.1.4.1.674.10892.2"
BMC_OID=".1.3.6.1.4.1.674.10892.2" # Dell iDRAC
### Forward Traps from the Service Processor to trap sink
# Name: TRAP_FORWARD
# Description: Enabling this will allow traps from the Service Processor
# to be directed to this system and configure snmptrapd
# Note: This option will have no effect if trap sink on the system is
# not configured
# Default: "no"
TRAP_FORWARD="yes"
### Reload snmpd and snmptrapd
# Name: RELOAD_SERVICES
# Description: Reload snmpd and snmptrapd after making changes to their config
# files.
# Default: "yes"
RELOAD_SERVICES="yes"

308
contrib/bmclanconf Executable file
View File

@@ -0,0 +1,308 @@
#!/bin/bash
#
# Copyright (c) 2003 Sun Microsystems, Inc. All Rights Reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions
# are met:
#
# Redistribution of source code must retain the above copyright
# notice, this list of conditions and the following disclaimer.
#
# Redistribution in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
#
# Neither the name of Sun Microsystems, Inc. or the names of
# contributors may be used to endorse or promote products derived
# from this software without specific prior written permission.
#
# This software is provided "AS IS," without a warranty of any kind.
# ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
# INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A
# PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE HEREBY EXCLUDED.
# SUN MICROSYSTEMS, INC. ("SUN") AND ITS LICENSORS SHALL NOT BE LIABLE
# FOR ANY DAMAGES SUFFERED BY LICENSEE AS A RESULT OF USING, MODIFYING
# OR DISTRIBUTING THIS SOFTWARE OR ITS DERIVATIVES. IN NO EVENT WILL
# SUN OR ITS LICENSORS BE LIABLE FOR ANY LOST REVENUE, PROFIT OR DATA,
# OR FOR DIRECT, INDIRECT, SPECIAL, CONSEQUENTIAL, INCIDENTAL OR
# PUNITIVE DAMAGES, HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF
# LIABILITY, ARISING OUT OF THE USE OF OR INABILITY TO USE THIS SOFTWARE,
# EVEN IF SUN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
# This script is designed for Sun Fire LX50, V60x and V65x systems.
# It may work with other setups as long as you use the correct channel
# and interface settings. It can be used on the V20z as long as you
# specify network settings on the command line.
#
# If the wrong channel is used you could lose network access to the
# box because your BMC will be sending out bad Gratuitous ARP packets
# with the wrong MAC address. You will need to use a console or
# override your local ARP cache with the correct addr.
usage ()
{
echo "
usage: $0 -c <chan> -i <interface> [options]
$0 -c <chan> [-v|w|x|y|z address] [options]
-c channel Which BMC channel to configure [-c help for more info]
-i interface Auto-configure BMC based on interface network settings
-v address Use specified IP address
-w address Use specified Netmask address
-x address Use specified MAC address
-y address Use specified Gateway IP address
-z address Use specified Gateway MAC address
-m interface Which IPMI interface to use [default linux=open solaris=lipmi]
-p password Set BMC channel password
-s string Set SNMP community string
-a interval Set Gratuitous ARP interval, off=0, default=4
-r Reset BMC channel, zero all network settings, disable
-d Debug mode, does not make any changes
"
exit 0;
}
channel_usage ()
{
echo "
Sun Fire V60x and V65x - Linux 2.4
eth0 = channel 6, top
eth1 = channel 7, bottom
Sun Fire V60x and V65x - Linux 2.6
eth0 = channel 7, bottom
eth1 = channel 6, top
Sun Fire V60x and V65x - Solaris x86
e1000g0 = channel 7, bottom
e1000g1 = channel 6, top
Sun LX50 - Linux
eth0 = channel 7, bottom
eth1 = channel 6, top
Sun LX50 - Solaris x86
le0 = channel 7, bottom
le1 = channel 6, top
Sun Fire V20z (-i option does not apply)
channel 1
"
exit 0
}
hex_to_ip ()
{
test $# -ge 1 || return;
local HEX B1 B2 B3 B4;
HEX=`echo $1 | tr '[:lower:]' '[:upper:]'`;
H1=`echo $HEX | cut -c1-2`
H2=`echo $HEX | cut -c3-4`
H3=`echo $HEX | cut -c5-6`
H4=`echo $HEX | cut -c7-8`
B1=`echo 10 o 16 i $H1 p | dc`
B2=`echo 10 o 16 i $H2 p | dc`
B3=`echo 10 o 16 i $H3 p | dc`
B4=`echo 10 o 16 i $H4 p | dc`
echo "$B1.$B2.$B3.$B4"
}
ipmitool_lan_set ()
{
[ $# -lt 1 ] && return
local PARAM=$1
local VALUE=
[ $# -ge 2 ] && VALUE=$2
if [ $DEBUG -gt 0 ]; then
echo "Setting LAN parameter $PARAM $VALUE"
echo "$IPMITOOL -I $IPMIINTF lan set $CHANNEL $PARAM $VALUE"
return
fi
$IPMITOOL -I $IPMIINTF lan set $CHANNEL $PARAM $VALUE
}
ipmitool_lan_reset ()
{
ipmitool_lan_set "ipsrc" "static"
ipmitool_lan_set "ipaddr" "0.0.0.0"
ipmitool_lan_set "netmask" "0.0.0.0"
ipmitool_lan_set "macaddr" "00:00:00:00:00:00"
ipmitool_lan_set "defgw ipaddr" "0.0.0.0"
ipmitool_lan_set "defgw macaddr" "00:00:00:00:00:00"
ipmitool_lan_set "password"
ipmitool_lan_set "snmp" "public"
ipmitool_lan_set "arp generate" "off"
ipmitool_lan_set "access" "off"
exit 0
}
DEBUG=0
LINUX=0
SOLARIS=0
CHANNEL=0
IFACE=
PASSWORD=
SNMP=
GRATARP=8
PATH=$PATH:/bin:/sbin:/usr/bin:/usr/sbin
case `uname -s` in
Linux)
IPMIINTF=open
IPMITOOL=ipmitool
PING=ping
IFCONFIG=ifconfig
ARP=arp
ROUTE=route
;;
SunOS)
IPMIINTF=lipmi
IPMITOOL=ipmiadm
PING=ping
IFCONFIG=ifconfig
ARP=arp
ROUTE=route
;;
*)
echo "Invalid OS!"
exit 1
esac
while getopts "dhri:c:m:p:s:a:v:w:x:y:z:" OPTION ; do
case "$OPTION" in
i) IFACE=$OPTARG ;;
c) CHANNEL=$OPTARG ; test X$CHANNEL = Xhelp && channel_usage ;;
m) IPMIINTF=$OPTARG ;;
p) PASSWORD=$OPTARG ;;
s) SNMP=$OPTARG ;;
a) GRATARP=$OPTARG ;;
d) DEBUG=1 ;;
v) IP_ADDRESS=$OPTARG ;;
w) IP_NETMASK=$OPTARG ;;
x) MAC_ADDRESS=$OPTARG ;;
y) GATEWAY_IP=$OPTARG ;;
z) GATEWAY_MAC=$OPTARG ;;
r) ipmitool_lan_reset ;;
h) usage ;;
*) echo "Ignoring invalid option : -$OPTARG" ;;
esac
done
if [ ! -x `which $IPMITOOL` ]; then
echo "Error: unable to find $IPMITOOL"
exit 1
fi
if [ $CHANNEL -eq 0 ]; then
echo
echo "Error: you must specify a channel with -c"
echo
exit 1
fi
if [ "$IFACE" ]; then
if ! $IFCONFIG $IFACE 2>/dev/null | grep "inet " >/dev/null 2>&1 ; then
echo
echo "Error: unable to find interface $IFACE"
echo
exit 1
fi
echo "Auto-configuring $IFACE (channel $CHANNEL)"
fi
case `uname -s` in
SunOS)
if [ X$IFACE != X ]; then
if [ X$IP_ADDRESS = X ]; then
IP_ADDRESS=`$IFCONFIG $IFACE | grep inet | awk '{print $2}'`
fi
if [ X$IP_NETMASK = X ]; then
HEX_NETMASK=`$IFCONFIG $IFACE | grep netmask | awk '{print $4}'`
IP_NETMASK=`hex_to_ip $HEX_NETMASK`
fi
if [ X$MAC_ADDRESS = X ]; then
MAC_ADDRESS=`$IFCONFIG $IFACE | grep ether | awk '{print $2}'`
fi
if [ X$GATEWAY_IP = X ]; then
GATEWAY_IP=`$ROUTE -n get default | grep gateway: | awk '{print $2}'`
fi
if [ X$GATEWAY_MAC = X ]; then
$PING -i $IFACE $GATEWAY_IP 1 >/dev/null 2>&1
GATEWAY_MAC=`$ARP $GATEWAY_IP | awk '{print $4}'`
if [ X$GATEWAY_MAC = Xno ]; then
GATEWAY_MAC=
fi
fi
fi
;;
Linux)
if [ X$IFACE != X ]; then
if [ X$IP_ADDRESS = X ]; then
IP_ADDRESS=`$IFCONFIG $IFACE | grep "inet addr" | awk -F"[:[:space:]]+" '{print $4}'`
fi
if [ X$IP_NETMASK = X ]; then
IP_NETMASK=`$IFCONFIG $IFACE | grep Bcast | awk -F"[:[:space:]]+" '{print $8}'`
fi
if [ X$MAC_ADDRESS = X ]; then
MAC_ADDRESS=`$IFCONFIG $IFACE | grep HWaddr | awk '{print $5}'`
fi
if [ X$GATEWAY_IP = X ]; then
GATEWAY_IP=`$ROUTE -n | awk '/^0.0.0.0/ {print $2}'`
fi
if [ X$GATEWAY_MAC = X ]; then
$PING -q -c1 $GATEWAY_IP >/dev/null 2>&1
GATEWAY_MAC=`$ARP -an | grep "$GATEWAY_IP[^0-9]" | awk '{print $4}'`
fi
fi
;;
esac
if [ X$IP_ADDRESS != X ]; then
ipmitool_lan_set "ipsrc" "static"
ipmitool_lan_set "ipaddr" "$IP_ADDRESS"
fi
if [ X$IP_NETMASK != X ]; then
ipmitool_lan_set "netmask" "$IP_NETMASK"
fi
if [ X$MAC_ADDRESS != X ]; then
ipmitool_lan_set "macaddr" "$MAC_ADDRESS"
fi
if [ X$GATEWAY_IP != X ]; then
ipmitool_lan_set "defgw ipaddr" "$GATEWAY_IP"
fi
if [ X$GATEWAY_MAC != X ]; then
ipmitool_lan_set "defgw macaddr" "$GATEWAY_MAC"
fi
if [ X$PASSWORD != X ]; then
ipmitool_lan_set "password" "$PASSWORD"
fi
if [ X$SNMP != X ]; then
ipmitool_lan_set "snmp" "$SNMP"
fi
if [ "$GRATARP" -ne 0 ]; then
ipmitool_lan_set "arp generate" "on"
ipmitool_lan_set "arp interval" "$GRATARP"
else
ipmitool_lan_set "arp generate" "off"
fi
echo "Setting channel authentication capabilities"
ipmitool_lan_set "auth callback,user,operator,admin" "md2,md5"
echo "Enabling channel $CHANNEL"
ipmitool_lan_set "access" "on"
ipmitool_lan_set "user"
exit 0

29
contrib/collect_data.sh Executable file
View File

@@ -0,0 +1,29 @@
#!/bin/bash
#
# Copyright (c) 2003 Fredrik Ohrn. All Rights Reserved.
#
# See the included COPYING file for license details.
#
# Edit the variables
hostname=$HOSTNAME
ipmi_cmd="/usr/local/bin/ipmitool -I open"
rrd_dir="/some/dir/rrd"
# No need to edit below this point.
IFS="
"
for line in `eval $ipmi_cmd -c sdr list full` ; do
IFS=,
split=($line)
file="$rrd_dir/$hostname-${split[0]}.rrd"
rrdupdate "$file" "N:${split[1]}"
done

40
contrib/create_rrds.sh Executable file
View File

@@ -0,0 +1,40 @@
#!/bin/bash
#
# Copyright (c) 2003 Fredrik Ohrn. All Rights Reserved.
#
# See the included COPYING file for license details.
#
# Edit the variables
hostname=$HOSTNAME
ipmi_cmd="/usr/local/bin/ipmitool -I open"
rrd_dir="/some/dir/rrd"
# No need to edit below this point.
IFS="
"
for line in `eval $ipmi_cmd -c -v sdr list full` ; do
IFS=,
split=($line)
file="$rrd_dir/$hostname-${split[0]}.rrd"
if [ -e "$file" ] ; then
echo "Skipping existing file $file"
continue
fi
echo "Creating file $file"
rrdtool create "$file" \
--step 300 DS:var:GAUGE:900:${split[16]}:${split[17]} \
RRA:AVERAGE:0.5:1:288 \
RRA:AVERAGE:0.5:6:336 \
RRA:AVERAGE:0.5:12:720
done

211
contrib/create_webpage.sh Executable file
View File

@@ -0,0 +1,211 @@
#!/bin/bash
#
# Copyright (c) 2003-2004 Fredrik Ohrn. All Rights Reserved.
#
# See the included COPYING file for license details.
#
# Edit the variables
hostname=$HOSTNAME
ipmi_cmd="/usr/local/bin/ipmitool -I open"
rrd_dir="/some/dir/rrd"
# Full path to the rrdcgi executable.
rrdcgi=/usr/local/bin/rrdcgi
# Where should rrdcgi store the graphs? This path must be within the
# document root and writable by the webserver user.
img_dir=/usr/local/apache2/htdocs/images/graphs
# Where will the graphs show up on the webserver?
web_dir=/images/graphs
# Size of graph area (excluding title, legends etc.)
graph_width=500
graph_height=150
# Graphs to include on page
graph_daily=1
graph_weekly=1
graph_monthly=0
# No need to edit below this point.
color[0]="2020FF"
color[1]="20FF20"
color[2]="FF2020"
color[3]="FF21FF"
color[4]="21FFFF"
color[5]="FFFF21"
color[6]="8F21FF"
color[7]="21FF8F"
color[8]="FF8F21"
color[9]="FF2190"
color[10]="2190FF"
color[11]="90FF21"
cat << EOF
#!$rrdcgi
<html>
<head>
<title>$hostname</title>
<RRD::GOODFOR 300>
<body>
<h2>$hostname</h2>
EOF
IFS="
"
i=0
groups=
for line in `eval $ipmi_cmd -c -v sdr list full` ; do
IFS=,
split=($line)
file="$rrd_dir/$hostname-${split[0]}.rrd"
group=`echo "${split[2]} ${split[*]:10:6}" | tr ' .-' ___`
group_color=${group}_color
if [ -z "${!group}" ] ; then
groups="$groups $group"
declare $group_color=0
group_unit=${group}_unit
declare $group_unit="${split[2]}"
group_title=${group}_title
declare $group_title="${split[5]} / ${split[6]}"
group_thres=${group}_thres
declare $group_thres="${split[10]},${split[11]},${split[12]},${split[13]},${split[14]},${split[15]}"
fi
declare $group="${!group}
DEF:var$i=\"$file\":var:AVERAGE LINE1:var$i#${color[${!group_color}]}:\"${split[0]}\""
declare $group_color=$[ ${!group_color} + 1 ]
c=$[ c + 1 ]
i=$[ i + 1 ]
done
IFS=" "
for group in $groups ; do
group_unit=${group}_unit
group_title=${group}_title
group_thres=${group}_thres
IFS=,
split=(${!group_thres})
thres=
if [ -n "${split[0]}" ] ; then
if [ -n "${split[3]}" ] ; then
thres="
HRULE:${split[0]}#000000
HRULE:${split[3]}#000000:\"Upper & lower non-recoverable thresholds\""
else
thres="
HRULE:${split[0]}#000000:\"Upper non-recoverable threshold\""
fi
else
if [ -n "${split[3]}" ] ; then
thres="
HRULE:${split[3]}#000000:\"Lower non-recoverable threshold\""
fi
fi
if [ -n "${split[1]}" ] ; then
if [ -n "${split[4]}" ] ; then
thres="$thres
HRULE:${split[1]}#FF0000
HRULE:${split[4]}#FF0000:\"Upper & lower critical thresholds\""
else
thres="$thres
HRULE:${split[1]}#FF0000:\"Upper critical threshold\""
fi
else
if [ -n "${split[4]}" ] ; then
thres="$thres
HRULE:${split[4]}#FF0000:\"Lower critical threshold\""
fi
fi
if [ -n "${split[2]}" ] ; then
if [ -n "${split[5]}" ] ; then
thres="$thres
HRULE:${split[2]}#FFCC00
HRULE:${split[5]}#FFCC00:\"Upper & lower warning thresholds\""
else
thres="$thres
HRULE:${split[2]}#FFCC00:\"Upper warning threshold\""
fi
else
if [ -n "${split[5]}" ] ; then
thres="$thres
HRULE:${split[5]}#FFCC00:\"Lower warning threshold\""
fi
fi
echo "<h3>${!group_title}</h3>"
if [ "$graph_daily" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-daily.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--vertical-label "${!group_unit}"
--title "Daily graph"
--height $graph_height
--width $graph_width ${!group} $thres
>
EOF
fi
if [ "$graph_weekly" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-weekly.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--start -7d
--vertical-label "${!group_unit}"
--title "Weelky graph"
--height $graph_height
--width $graph_width ${!group} $thres
>
EOF
fi
if [ "$graph_monthly" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-monthly.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--start -30d
--vertical-label "${!group_unit}"
--title "Monthly graph"
--height $graph_height
--width $graph_width ${!group} $thres
>
EOF
fi
done
cat << EOF
</body>
</html>
EOF

151
contrib/create_webpage_compact.sh Executable file
View File

@@ -0,0 +1,151 @@
#!/bin/bash
#
# Copyright (c) 2003-2004 Fredrik Ohrn. All Rights Reserved.
#
# See the included COPYING file for license details.
#
# Edit the variables
hostname=$HOSTNAME
ipmi_cmd="/usr/local/bin/ipmitool -I open"
rrd_dir="/some/dir/rrd"
# Full path to the rrdcgi executable.
rrdcgi=/usr/local/bin/rrdcgi
# Where should rrdcgi store the graphs? This path must be within the
# document root and writable by the webserver user.
img_dir=/usr/local/apache2/htdocs/images/graphs
# Where will the graphs show up on the webserver?
web_dir=/images/graphs
# Size of graph area (excluding title, legends etc.)
graph_width=500
graph_height=150
# Graphs to include on page
graph_daily=1
graph_weekly=1
graph_monthly=0
# No need to edit below this point.
color[0]="2020FF"
color[1]="20FF20"
color[2]="FF2020"
color[3]="FF21FF"
color[4]="21FFFF"
color[5]="FFFF21"
color[6]="8F21FF"
color[7]="21FF8F"
color[8]="FF8F21"
color[9]="FF2190"
color[10]="2190FF"
color[11]="90FF21"
cat << EOF
#!$rrdcgi
<html>
<head>
<title>$hostname</title>
<RRD::GOODFOR 300>
<body>
<h2>$hostname</h2>
EOF
IFS="
"
i=0
groups=
for line in `eval $ipmi_cmd -c -v sdr list full` ; do
IFS=,
split=($line)
file="$rrd_dir/$hostname-${split[0]}.rrd"
group=`echo "${split[2]}" | tr ' .-' ___`
group_color=${group}_color
if [ -z "${!group}" ] ; then
groups="$groups $group"
declare $group_color=0
group_unit=${group}_unit
declare $group_unit="${split[2]}"
fi
declare $group="${!group}
DEF:var$i=\"$file\":var:AVERAGE LINE1:var$i#${color[${!group_color}]}:\"${split[0]}\""
declare $group_color=$[ ${!group_color} + 1 ]
c=$[ c + 1 ]
i=$[ i + 1 ]
done
IFS=" "
for group in $groups ; do
group_unit=${group}_unit
IFS=,
echo "<h3>${!group_unit}</h3>"
if [ "$graph_daily" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-daily.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--vertical-label "${!group_unit}"
--title "Daily graph"
--height $graph_height
--width $graph_width ${!group}
>
EOF
fi
if [ "$graph_weekly" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-weekly.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--start -7d
--vertical-label "${!group_unit}"
--title "Weelky graph"
--height $graph_height
--width $graph_width ${!group}
>
EOF
fi
if [ "$graph_monthly" -ne 0 ] ; then
cat << EOF
<RRD::GRAPH "$img_dir/$hostname-$group-monthly.gif"
--imginfo "<img src="$web_dir/%s" width="%lu" height="%lu">"
--lazy
--start -30d
--vertical-label "${!group_unit}"
--title "Monthly graph"
--height $graph_height
--width $graph_width ${!group}
>
EOF
fi
done
cat << EOF
</body>
</html>
EOF

View File

@@ -0,0 +1,326 @@
#!/bin/sh
#############################################################################
#
# exchange-bmc-os-info: Set OS and BMC (Baseboard Management Controller)
# parameters during system startup.
#
# version: 0.72
#
# Authors: Charles Rose <charles_rose@dell.com>
# Jordan Hargrave <jordan_hargrave@dell.com>
#
# Description: Script to set OS information in the BMC; fetch BMC IP/URL
# and set in the OS for use by other scripts/user.
#
# BMC IP and URL are made available in /var/run/bmc-info
#
# Example to launch BMC web-interface:
# # . /var/run/bmc-info
# # xdg-open $BMC_URL
#
# See here for details:
# https://fedoraproject.org/wiki/Features/AgentFreeManagement
#
# OEM Specific: OEM specific ipmi commands go in:
# 'oem_set_os_version' and 'oem_get_bmc_url'
#############################################################################
#
# chkconfig: 345 99 00
# description: Set OS name, hostname in BMC; make BMC IP/URL available in OS
# processname: exchange-bmc-os-info
# config: /etc/sysconfig/exchange-bmc-os-info
#
### BEGIN INIT INFO
# Provides: exchange-bmc-os-info
# Required-Start: ipmi
# Default-Start: 3 4 5
# Default-Stop: 0 1 2 6
#############################################################################
# GLOBALS
#############################################################################
CONFIGFILE=/etc/sysconfig/exchange-bmc-os-info
IPMI_TOOL=/usr/bin/ipmitool
BMC_INFO=/var/run/bmc-info
# BMC Manufacturer ID used in 'oem_set_os_version' and 'oem_get_bmc_url'
DELL="674"
#OTHER_OEM="123"
# Defaults for ${CONFIGFILE}
SET_OS_INFO="yes"
RESET_OS_INFO="no"
SET_BMC_INFO="yes"
# getsysinfo and setsysinfo commands
IPMI_SET_SYSINFO="${IPMI_TOOL} mc setsysinfo"
IPMI_GET_SYSINFO="${IPMI_TOOL} mc getsysinfo"
#############################################################################
SCRIPT_NAME=$(basename $0)
# source config
[ -r ${CONFIGFILE} ] && . ${CONFIGFILE}
RETVAL=0
if [ -f /bin/gettext.sh ]; then
GETTEXT=1
. /bin/gettext.sh
OUTPUT="eval_gettext"
else
GETTEXT=0
OUTPUT="echo"
fi
#############################################################################
# Get Vendor ID of BMC for use in 'oem_set_os_version' and 'oem_get_bmc_url'
#
get_bmc_vendor_id()
{
BMC_VENDOR=$(${IPMI_TOOL} mc info 2>/dev/null | \
sed -n "s#^Manufacturer ID.*: ##p")
[ -z "${BMC_VENDOR}" ] && RETVAL=4
}
check_ipmitool()
{
if [ -x ${IPMI_TOOL} ]; then
# v1.8.12 plus patches are required for set/getsysinfo support
# http://sourceforge.net/mailarchive/message.php?msg_id=29647222
[ ! ${IPMI_GET_SYSINFO} >/dev/null 2>&1 ] && \
RETVAL=3
else
RETVAL=2
fi
}
bmc_exists()
{
check_ipmitool
[ $RETVAL -eq 0 ] && get_bmc_vendor_id
return $RETVAL
}
#############################################################################
get_os_info()
{
OS_HOSTNAME=$(hostname)
KERNEL_VERSION=$(uname -r -m)
if [ -e /etc/lsb-release ] ; then
. /etc/lsb-release
NAME=${DISTRIB_ID}
VERSION="${DISTRIB_RELEASE} ${DISTRIB_CODENAME}"
fi
# we prefer systemd's /etc/os-release over other sources
[ -e /etc/os-release ] && . /etc/os-release
OS_NAME=${NAME}
OS_VERSION="${VERSION} kernel ${KERNEL_VERSION}"
}
oem_set_os_version()
{
# OS Version setting is not standard yet
# we need per vendor oem commands
case "${BMC_VENDOR}" in
$DELL) ${IPMI_SET_SYSINFO} delloem_os_version \
"${OS_VERSION}" > /dev/null 2>&1
return $?
;;
# Add OEM specific commands.
# Example:
# $OTHER_OEM) ${IPMI_SET_SYSINFO} otheroem_os_version \
# "${OS_VERSION}" > /dev/null 2>&1
# return $?
# ;;
*) return 0
;;
esac
}
set_os_info()
{
# Set and reset OS info in the BMC
if [ "$1" = "reset" ]; then
OS_NAME=""
OS_HOSTNAME=""
OS_VERSION=""
fi
${IPMI_SET_SYSINFO} os_name "${OS_NAME}" >/dev/null 2>&1 \
|| RETVAL=6
${IPMI_SET_SYSINFO} primary_os_name "${OS_NAME}" >/dev/null 2>&1 \
|| RETVAL=6
${IPMI_SET_SYSINFO} system_name "${OS_HOSTNAME}" >/dev/null 2>&1 \
|| RETVAL=6
oem_set_os_version || RETVAL=6
}
#############################################################################
valid_url()
{
url="(https?|http)://[a-z0-9-]+(\.[a-z0-9-]+)+([/?].*)?"
printf -- "%s" "${TMP_URL}"| grep -Eq "^${url}"
return $?
}
oem_get_bmc_url()
{
# BMC URL is not standard yet
# we need per vendor oem commands
case "$BMC_VENDOR" in
$DELL) TMP_URL=$(${IPMI_GET_SYSINFO} delloem_url 2> /dev/null)
;;
# Add OEM specific commands
# Example:
# $OTHER_OEM)
# TMP_URL=$(${IPMI_GET_SYSINFO} otheroem_url 2> /dev/null)
# ;;
*) TMP_URL="" ;;
esac
valid_url && BMC_URL=${TMP_URL} || BMC_URL=""
}
valid_ip()
{
#Thanks to mkyong.com
octet="([01]?[[:digit:]][[:digit:]]?|2[0-4][[:digit:]]|25[0-5])"
printf -- "%s" "${TMP_IPv4}"| grep -Eq "^${octet}\\.${octet}\\.${octet}\\.${octet}$"
return $?
}
get_bmc_ip()
{
#Thanks to http://ingvar.blog.redpill-linpro.com
for CHANNEL in `seq 1 14`
do
[ $(${IPMI_TOOL} lan print ${CHANNEL} 2>/dev/null \
| grep -q "^Set") ] || break
done
# Get BMC_IPv4 and BMC_URL from BMC
TMP_IPv4=$(${IPMI_TOOL} lan print ${CHANNEL} 2>/dev/null \
| sed -n "s#^IP Address .*: ##p")
valid_ip && BMC_IPv4=${TMP_IPv4} || BMC_IPv4=""
}
get_bmc_info()
{
get_bmc_ip
if [ -z "${BMC_IPv4}" ] || [ "${BMC_IPv4}" = "0.0.0.0" ]; then
BMC_IPv4=""
RETVAL=5
else
# URL makes sense only if there is an IP
oem_get_bmc_url
fi
}
set_bmc_info()
{
if [ ! $(touch "${BMC_INFO}" && chmod 600 "${BMC_INFO}") ]; then
printf "BMC_IPv4=%s\n" "${BMC_IPv4}" > "${BMC_INFO}"
[ -n "${BMC_URL}" ] && \
printf "BMC_URL=%s\n" "${BMC_URL}" >> "${BMC_INFO}"
else
RETVAL=5
fi
}
unset_bmc_info()
{
[ -f ${BMC_INFO} ] && rm -f ${BMC_INFO} > /dev/null 2>&1
}
#############################################################################
start()
{
if bmc_exists; then
[ "${SET_OS_INFO}" = "yes" ] && \
get_os_info && set_os_info
if [ "${SET_BMC_INFO}" = "yes" ]; then
get_bmc_info
if [ ${RETVAL} -eq 0 ]; then
set_bmc_info
fi
fi
fi
}
#############################################################################
stop()
{
if bmc_exists; then
# reset OS info while system reboots
# aids with debugging OS boot-up issues
if [ "${RESET_OS_INFO}" = "yes" ]; then
set_os_info reset
fi
unset_bmc_info
fi
}
#############################################################################
restart()
{
stop
[ $RETVAL -eq 0 ] && start
}
#############################################################################
status()
{
[ -r ${BMC_INFO} ] && \
grep -q "BMC_IPv4" "${BMC_INFO}" >/dev/null 1>&2 && \
BMC_STATUS="ok" || BMC_STATUS="inactive"
${OUTPUT} "${SCRIPT_NAME}: ${BMC_STATUS}" 1>&2
[ ${GETTEXT} -eq 1 ] && echo
}
#############################################################################
usage()
{
${OUTPUT} "Usage: ${SCRIPT_NAME} {start|stop|restart|status}" 1>&2
[ ${GETTEXT} -eq 1 ] && echo
RETVAL=1
}
#############################################################################
# MAIN
#############################################################################
case "$1" in
start) start ;;
stop) stop ;;
restart) restart ;;
status) status ;;
*) usage ;;
esac
case "$RETVAL" in
0|1) ;;
2) ${OUTPUT} "${SCRIPT_NAME}: ipmitool(1) not found." 1>&2 ;;
3) ${OUTPUT} "${SCRIPT_NAME}: this version of ipmitool does not support getsysinfo." 1>&2 ;;
4) ${OUTPUT} "${SCRIPT_NAME}: failed to communicate with BMC." 1>&2 ;;
5) ${OUTPUT} "${SCRIPT_NAME}: failed to set OS information in BMC." 1>&2 ;;
6) ${OUTPUT} "${SCRIPT_NAME}: failed to get BMC information." 1>&2 ;;
*) ${OUTPUT} "${SCRIPT_NAME}: unexpected error." 1>&2 ;;
esac
if [ ${RETVAL} -gt 1 ]; then
${OUTPUT} " Return code: ${RETVAL}" 1>&2
[ ${GETTEXT} -eq 1 ] && echo
fi
exit ${RETVAL}
#############################################################################
# end of file
#############################################################################

View File

@@ -0,0 +1,13 @@
[Unit]
Description=Exchange Information between BMC and OS
After=ipmi.service network.target
Requires=ipmi.service
[Service]
Type=oneshot
RemainAfterExit=yes
ExecStart=/usr/libexec/exchange-bmc-os-info start
ExecStop=/usr/libexec/exchange-bmc-os-info stop
[Install]
WantedBy=multi-user.target

View File

@@ -0,0 +1,26 @@
# exchange-bmc-os-info
#
# Config file to control Exchange of information between
# the OS and Service Processor/Baseboard Management Controller (BMC)
#
# See here for details
# https://fedoraproject.org/wiki/Features/AgentFreeManagement
### Set OS Info in BMC/Service Processor ###
# Name: SET_OS_INFO
# Description: Set OS Name, Version and Hostname in the Service Processor (BMC)
# Default: yes
SET_OS_INFO="yes"
### Reset OS Info in BMC/Service Processor ###
# Name: RESET_OS_INFO
# Description: Reset OS Name, Version and Hostname in the Service Processor (BMC).
# Useful when the OS Name/Hostname should be empty on reboot
# Default: no
RESET_OS_INFO="no"
### Set BMC/Service Processor Info in OS ###
# Name; SET_BMC_INFO
# Description: Set IP Address and URL of Service Processor/BMC in /run/bmc-info
# Default: yes
SET_BMC_INFO="yes"

17
contrib/ipmi.init.basic Executable file
View File

@@ -0,0 +1,17 @@
#!/bin/sh
echo "Setting up OpenIPMI driver..."
# load the ipmi modules
modprobe ipmi_msghandler
modprobe ipmi_devintf
if ! modprobe ipmi_si_drv ; then
modprobe ipmi_si # try new module name
fi
maj=$(cat /proc/devices | awk '/ipmidev/{print $1}')
if [ "$maj" ]; then
test -e /dev/ipmi0 && rm -f /dev/ipmi0
/bin/mknod /dev/ipmi0 c $maj 0
fi

222
contrib/ipmi.init.redhat Executable file
View File

@@ -0,0 +1,222 @@
#!/bin/sh
#
# chkconfig: 2345 11 60
# description: start, stop, or query ipmi system monitoring tools
# config: /etc/sysconfig/ipmi
#
# For Redhat, Fedora, or similar systems. Handles both 2.4 and 2.6
# configurations. Requires an /etc/sysconfig/ipmi file to function,
# see below.
#
# Phil Hollenback
# philiph@pobox.com
# Source function library.
. /etc/init.d/functions
# Exit silently if we don't have a sysconfig file,
# and read IPMI setting from it to determine whether or
# not to continue.
# The only current setting is ipmi={YES|NO}, whether or not
# to enable IPMI.
[ -f /etc/sysconfig/ipmi ] || exit 0
. /etc/sysconfig/ipmi
[ "${IPMI}" = "yes" ] || exit 0
RETVAL=0
start() {
echo -n $"Starting ipmi: "
# If ipmidev isn't listed in /proc/devices, try
# loading the modules.
if ! grep -q ipmidev /proc/devices
then
/sbin/modprobe ipmi_msghandler || RETVAL=1
/sbin/modprobe ipmi_devintf || RETVAL=1
# Try loading new driver module, fall back to old
# module if that fails.
if ! /sbin/modprobe ipmi_si >/dev/null 2>&1
then
/sbin/modprobe ipmi_si_drv || RETVAL=1
fi
fi
# If ipmidev still isn't listed in /proc/devices after we load
# modules, this just isn't going to work. Set RETVAL to mark
# this failure.
grep -q ipmidev /proc/devices || RETVAL=1
# remove old device file always
# in case ipmi gets assigned new dynamic major number from kernel
if [ -c /dev/ipmi0 ]; then
rm -f /dev/ipmi0
fi
# Check if the device file exists and create if not.
if [ ! -c /dev/ipmi0 ] && [ $RETVAL -eq 0 ]
then
major=$(awk '/ ipmidev$/{print $1}' /proc/devices)
/bin/mknod -m 0600 /dev/ipmi0 c $major 0 || RETVAL=1
fi
if [ $RETVAL -eq 0 ] && touch /var/lock/subsys/ipmi ; then
echo_success
echo
else
echo_failure
echo
fi
}
stop() {
echo -n $"Shutting down ipmi: "
# Stop doesn't actually do anything because we currently don't
# unload ipmi modules on stop. That might change in the future
# if we decide unloading the ipmi modules is safe.
RETVAL=0
if [ $RETVAL -eq 0 ] && rm -f /var/lock/subsys/ipmi ; then
echo_success
echo
else
echo_failure
echo
fi
}
dostatus() {
# Extract cpu temperatures from ipmitool output.
# Abort if we don't have the ipmitool program.
if ! /usr/bin/ipmitool -V >/dev/null
then
echo "/usr/bin/ipmitool not found!" >&2
exit 1
fi
# Abort if ipmi isn't loaded.
if ! grep -q ipmidev /proc/devices
then
echo "ipmi not listed in /proc/devices!" >&2
exit 1
fi
# Check if we are running on a v1.0 IPMI system, and
# change our processor search string appropriately.
if /usr/bin/ipmitool -I open bmc info | \
grep -q "IPMI Version.*1.0"
then
IpmiVersion="1.0"
fi
# Determine # of running processors
NumProcs=$(grep -c processor /proc/cpuinfo)
if [ $NumProcs -eq 0 ]
then
echo "Can't determine number of processors!" >&2
exit 1
fi
# Now build the query string. Concatenate it into
# one string because that's more efficient on 2.4 systems.
Count=1
TempString=""
while [ $Count -le $NumProcs ]
do
if [ x$IpmiVersion = x"1.0" ]
then
TempString="$TempString CPU\ $Count"
else
TempString="$TempString Processor$Count\ Temp"
fi
Count=$((Count + 1))
done
# building TempString like this and eval'ing it is ugly, but
# it's the only way I could make the quoting work. Sorry.
TempString="/usr/bin/ipmitool -I open sensor get $TempString"
eval $TempString | awk -v "c=$Count" '
BEGIN {
n = 1
}
/Sensor Reading/ {
printf "CPU%s Temp: %s\n",n,$4
n++
}
END {
if ( n != c) {
printf "Error: found %s CPUs, but got temps for %s\n",--c,--n >"/dev/stderr"
exit 1
}
exit 0
}'
RETVAL=$((RETVAL + $?))
return $RETVAL
}
restart() {
stop
start
RETVAL=$?
}
condrestart() {
[ -e /var/lock/subsys/ipmi ] && restart || :
}
remove () {
# Actually remove the drivers. Don't do during stop in case
# this causes system to become unstable (a la lm_sensors)
if /sbin/lsmod | awk '{print $1}' | grep -q ipmi_
then
# Try removing both 2.4 and 2.6 modules.
/sbin/rmmod ipmi_si 2>/dev/null
/sbin/rmmod ipmi_si_drv 2>/dev/null
/sbin/rmmod ipmi_devintf
/sbin/rmmod ipmi_msghandler
else
echo "No ipmi modules loaded!" >&2
RETVAL=1
return $RETVAL
fi
# Wait a sec to give modules time to unload.
sleep 1
# Check if we failed to remove any modules, and complain if so.
if /sbin/lsmod | awk '{print $1}' | grep -q ipmi_
then
echo "ipmi modules still loaded!" >&2
RETVAL=1
return $RETVAL
fi
}
# See how we were called.
case "$1" in
start)
start
;;
stop)
stop
;;
status)
dostatus
;;
restart|reload)
restart
;;
condrestart)
condrestart
;;
remove)
remove
;;
*)
echo "Usage: ipmi {start|stop|status|restart|condrestart|remove}"
exit 1
esac
exit $RETVAL

92
contrib/ipmievd.init.debian Executable file
View File

@@ -0,0 +1,92 @@
#! /bin/sh
### BEGIN INIT INFO
# Provides: ipmievd
# Required-Start: $local_fs $remote_fs $syslog
# Required-Stop: $local_fs $remote_fs $syslog
# Default-Start: 2 3 4 5
# Default-Stop: S 0 1 6
# Short-Description: IPMI event daemon
# Description: ipmievd is a daemon which will listen for events
# from the BMC that are being sent to the SEL and
# also log those messages to syslog.
### END INIT INFO
#
# Author: Elmar Hoffmann <elho@elho.net>
# Licence: This script is public domain using the same
# licence as ipmitool itself.
# Modified by: Petter Reinholdtsen
set -e
PATH=/usr/local/sbin:/usr/local/bin:/sbin:/bin:/usr/sbin:/usr/bin
DESC="IPMI event daemon"
NAME=ipmievd
DAEMON=/usr/sbin/$NAME
PIDFILE=/var/run/$NAME.pid
SCRIPTNAME=/etc/init.d/$NAME
# Gracefully exit if the package has been removed.
test -x $DAEMON || exit 0
. /lib/lsb/init-functions
. /etc/default/rcS
# Options used by ipmievd.
#
# "open" uses the asynchronous event notification from the OpenIPMI
# kernel driver, "sel" uses active polling of the contents of the SEL
# for new events.
#
# Need to force 'daemon' mode, to make sure messages are sent to
# syslog and the program forks into the background.
#
# Se ipmievd(8) for more info.
IPMIEVD_OPTIONS="open daemon"
# Read config file if it is present.
[ -f /etc/default/$NAME ] && . /etc/default/$NAME
#
# Function that starts the daemon/service.
#
d_start() {
start-stop-daemon --start --quiet --exec $DAEMON -- $IPMIEVD_OPTIONS
}
#
# Function that stops the daemon/service.
#
d_stop() {
start-stop-daemon --stop --quiet --name $NAME --exec $DAEMON
}
CODE=0
case "$1" in
start)
[ "$VERBOSE" != no ] && log_begin_msg "Starting $DESC" "$NAME"
d_start || CODE=$?
[ "$VERBOSE" != no ] && log_end_msg $CODE
exit $CODE
;;
stop)
log_begin_msg "Stopping $DESC" "$NAME"
d_stop || CODE=$?
log_end_msg $CODE
exit $CODE
;;
restart|force-reload)
log_begin_msg "Restarting $DESC" "$NAME"
d_stop || true
sleep 1
d_start || CODE=$?
log_end_msg $CODE
exit $CODE
;;
*)
echo "Usage: $SCRIPTNAME {start|stop|restart|force-reload}" >&2
exit 1
;;
esac
exit 0

87
contrib/ipmievd.init.redhat Executable file
View File

@@ -0,0 +1,87 @@
#!/bin/bash
#
# /etc/rc.d/init.d/ipmievd
#
# Based on example sysvinitfiles script
# Copyright (c) 2000 Red Hat Software, Inc.
#
# chkconfig: 345 99 00
# description: ipmievd daemon to send events to syslog
# processname: ipmievd
# config: /etc/sysconfig/ipmievd
#
### BEGIN INIT INFO
# Provides: ipmievd
# Required-Start: $syslog ipmi
# Should-Start: $time
# Required-Stop: $syslog ipmi
# Should-Stop: $time
# Default-Start: 3 4 5
# Default-Stop: 0 1 2 6
# Short-Description: ipmievd daemon to send events to syslog
# Description: Start ipmievd to read events from BMC and
# log them to syslog. Events correspond to hardware faults,
# state transitions such as power on and off, and sensor
# readings such as temperature, voltage and fan speed that
# are abnormal.
### END INIT INFO
IPMIEVD_BIN=/usr/sbin/ipmievd
test -x $IPMIEVD_BIN || { echo "$IPMIEVD_BIN not installed";
if [ "$1" = "stop" ]; then exit 0;
else exit 5; fi; }
# Check for existence of needed config file
IPMIEVD_CONFIG=/etc/sysconfig/ipmievd
test -r $IPMIEVD_CONFIG || { echo "$IPMIEVD_CONFIG does not exist";
if [ "$1" = "stop" ]; then exit 0;
else exit 6; fi; }
# Read config file
. $IPMIEVD_CONFIG
# Source function library.
. /etc/init.d/functions
start() {
echo "Starting ipmievd:"
if [ -f /var/lock/subsys/ipmievd ]; then
return 0
fi
daemon $IPMIEVD_BIN $IPMIEVD_OPTIONS
ret=$?
[ $ret -eq 0 ] && touch /var/lock/subsys/ipmievd
return $ret
}
stop() {
echo "Shutting down ipmievd:"
killproc $IPMIEVD_BIN
ret=$?
[ $ret -eq 0 ] && rm -f /var/lock/subsys/ipmievd
return $ret
}
case "$1" in
start)
start
;;
stop)
stop
;;
status)
status $IPMIEVD_BIN
;;
restart|reload)
stop
start
;;
condrestart)
[ -f /var/lock/subsys/ipmievd ] && restart || :
;;
*)
echo "Usage: ipmievd {start|stop|status|reload|restart|condrestart}"
exit 1
;;
esac
exit $?

212
contrib/ipmievd.init.suse Executable file
View File

@@ -0,0 +1,212 @@
#!/bin/bash
#
# System startup script for ipmievd
# Based on skeleton.compat example script
# Copyright (C) 1995--2005 Kurt Garloff, SUSE / Novell Inc.
#
# This library is free software; you can redistribute it and/or modify it
# under the terms of the GNU Lesser General Public License as published by
# the Free Software Foundation; either version 2.1 of the License, or (at
# your option) any later version.
#
# This library is distributed in the hope that it will be useful, but
# WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
# Lesser General Public License for more details.
#
# You should have received a copy of the GNU Lesser General Public
# License along with this library; if not, write to the Free Software
# Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307,
# USA.
#
# Note: This template uses functions rc_XXX defined in /etc/rc.status on
# UnitedLinux/SUSE/Novell based Linux distributions. However, it will work
# on other distributions as well, by using the LSB (Linux Standard Base)
# or RH functions or by open coding the needed functions.
# Read http://www.tldp.org/HOWTO/HighQuality-Apps-HOWTO/ if you prefer not
# to use this template.
#
# chkconfig: 345 99 00
# description: ipmievd daemon
#
### BEGIN INIT INFO
# Provides: ipmievd
# Required-Start: $syslog ipmi
# Should-Start: $time
# Required-Stop: $syslog ipmi
# Should-Stop: $time
# Default-Start: 3 4 5
# Default-Stop: 0 1 2 6
# Short-Description: ipmievd daemon to send events to syslog
# Description: Start ipmievd to read events from BMC and
# log them to syslog. Events correspond to hardware faults,
# state transitions such as power on and off, and sensor
# readings such as temperature, voltage and fan speed that
# are abnormal.
### END INIT INFO
#
# Check for missing binaries (stale symlinks should not happen)
# Note: Special treatment of stop for LSB conformance
IPMIEVD_BIN=/usr/sbin/ipmievd
test -x $IPMIEVD_BIN || { echo "$IPMIEVD_BIN not installed";
if [ "$1" = "stop" ]; then exit 0;
else exit 5; fi; }
# Check for existence of needed config file and read it
IPMIEVD_CONFIG=/etc/sysconfig/ipmievd
test -r $IPMIEVD_CONFIG || { echo "$IPMIEVD_CONFIG does not exist";
if [ "$1" = "stop" ]; then exit 0;
else exit 6; fi; }
# Read config
. $IPMIEVD_CONFIG
if test -e /etc/rc.status; then
# SUSE rc script library
. /etc/rc.status
else
export LC_ALL=POSIX
_cmd=$1
declare -a _SMSG
if test "${_cmd}" = "status"; then
_SMSG=(running dead dead unused unknown reserved)
_RC_UNUSED=3
else
_SMSG=(done failed failed missed failed skipped unused failed failed reserved)
_RC_UNUSED=6
fi
if test -e /lib/lsb/init-functions; then
# LSB
. /lib/lsb/init-functions
echo_rc()
{
if test ${_RC_RV} = 0; then
log_success_msg " [${_SMSG[${_RC_RV}]}] "
else
log_failure_msg " [${_SMSG[${_RC_RV}]}] "
fi
}
# TODO: Add checking for lockfiles
checkproc() { return pidofproc ${1+"$@"} >/dev/null 2>&1; }
elif test -e /etc/init.d/functions; then
# RHAT
. /etc/init.d/functions
echo_rc()
{
#echo -n " [${_SMSG[${_RC_RV}]}] "
if test ${_RC_RV} = 0; then
success " [${_SMSG[${_RC_RV}]}] "
else
failure " [${_SMSG[${_RC_RV}]}] "
fi
}
checkproc() { return status ${1+"$@"}; }
start_daemon() { return daemon ${1+"$@"}; }
else
# emulate it
echo_rc() { echo " [${_SMSG[${_RC_RV}]}] "; }
fi
rc_reset() { _RC_RV=0; }
rc_failed()
{
if test -z "$1"; then
_RC_RV=1;
elif test "$1" != "0"; then
_RC_RV=$1;
fi
return ${_RC_RV}
}
rc_check()
{
return rc_failed $?
}
rc_status()
{
rc_failed $?
if test "$1" = "-r"; then _RC_RV=0; shift; fi
if test "$1" = "-s"; then rc_failed 5; echo_rc; rc_failed 3; shift; fi
if test "$1" = "-u"; then rc_failed ${_RC_UNUSED}; echo_rc; rc_failed 3; shift; fi
if test "$1" = "-v"; then echo_rc; shift; fi
if test "$1" = "-r"; then _RC_RV=0; shift; fi
return ${_RC_RV}
}
rc_exit() { exit ${_RC_RV}; }
rc_active()
{
if test -z "$RUNLEVEL"; then read RUNLEVEL REST < <(/sbin/runlevel); fi
if test -e /etc/init.d/S[0-9][0-9]${1}; then return 0; fi
return 1
}
fi
# Reset status of this service
rc_reset
# Return values acc. to LSB for all commands but status:
# 0 - success
# 1 - generic or unspecified error
# 2 - invalid or excess argument(s)
# 3 - unimplemented feature (e.g. "reload")
# 4 - user had insufficient privileges
# 5 - program is not installed
# 6 - program is not configured
# 7 - program is not running
# 8--199 - reserved (8--99 LSB, 100--149 distrib, 150--199 appl)
#
# Note that starting an already running service, stopping
# or restarting a not-running service as well as the restart
# with force-reload (in case signaling is not supported) are
# considered a success.
case "$1" in
start)
echo -n "Starting ipmievd "
start_daemon $IPMIEVD_BIN $IPMIEVD_OPTIONS
rc_status -v
;;
stop)
echo -n "Shutting down ipmievd "
killproc -TERM $IPMIEVD_BIN
rc_status -v
;;
try-restart|condrestart)
## Do a restart only if the service was active before.
## Note: try-restart is now part of LSB (as of 1.9).
## RH has a similar command named condrestart.
if test "$1" = "condrestart"; then
echo "${attn} Use try-restart ${done}(LSB)${attn} rather than condrestart ${warn}(RH)${norm}"
fi
$0 status
if test $? = 0; then
$0 restart
else
rc_reset # Not running is not a failure.
fi
rc_status
;;
restart)
$0 stop
$0 start
rc_status
;;
force-reload)
echo -n "Reload service ipmievd "
$0 try-restart
rc_status
;;
reload)
rc_failed 3
rc_status -v
;;
status)
echo -n "Checking for service ipmievd "
checkproc $IPMIEVD_BIN
rc_status -v
;;
*)
echo "Usage: $0 {start|stop|status|try-restart|restart|force-reload| reload}"
exit 1
;;
esac
rc_exit

229
contrib/oem_ibm_sel_map Normal file
View File

@@ -0,0 +1,229 @@
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x01","0x00","Chassis Number","R","R","0x00","CPU shutdown - Potential cause "triple fault" a software address problem"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x02","0x01","Chassis Number","Failed Memory Card","Spare Memory Card","0x00","Memory Mirrored Failover Occurred - System running from mirrored memory image"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x02","0x04","Chassis Number","Memory Card","Completion Code (0x00=Success)","0x00","Memory hot replace event"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x02","0x05","Chassis Number","Memory Card","Memory Size (in 512MB units)","0x00","Memory hot add event"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x00","Chassis Number","Scalability Port Number","R","0x00","Scalability link down"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","Chassis Number","Scalability Port Number","R","0x00","Scalability link up"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x02","Chassis Number","Scalability Port Number","R","0x00","Scalability link double wide down"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x03","Chassis Number","Scalability Port Number","R","0x00","Scalability link double wide up"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x80","Chassis Number","Scalability Port Number","R","0x00","Scalability link PFA"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x81","Chassis Number","Scalability Port Number","R","0x00","Scalability link invalid port"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x82","Chassis Number","Scalability Port Number","R","0x00","Scalability link invalid node"
"0xC1","XX","XX","XX","XX","XX","XX","XX","0x03","0x83","Chassis Number","Scalability Port Number","R","0x00","Scalability link kill"
"0xE0","0x00","0x00","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Device OK"
"0xE0","0x00","0x01","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Required ROM space not available"
"0xE0","0x00","0x02","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Required I/O Space not available"
"0xE0","0x00","0x03","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Required memory not available"
"0xE0","0x00","0x04","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Required memory below 1MB not available"
"0xE0","0x00","0x05","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","ROM checksum failed"
"0xE0","0x00","0x06","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","BIST failed"
"0xE0","0x00","0x07","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Planar device missing or disabled by user"
"0xE0","0x00","0x08","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","PCI device has an invalid PCI configuration space header"
"0xE0","0x00","0x09","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","FRU information for added PCI device"
"0xE0","0x00","0x0A","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","FRU information for removed PCI device"
"0xE0","0x00","0x0B","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","A PCI device was removed, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x0C","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","A PCI device was added, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x0D","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Requested resources not available"
"0xE0","0x00","0x13","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Planar video disabled due to add in video card"
"0xE0","0x00","0x14","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","FRU information for PCI device partially disabled "
"0xE0","0x00","0x15","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","A PCI device was partially disabled, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x16","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","A 33Mhz device is installed on a 66Mhz bus, PCI device information is stored in next log entry"
"0xE0","0x00","0x17","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","FRU information, 33Mhz device installed on 66Mhz bus"
"0xE0","0x00","0x18","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Merge cable missing"
"0xE0","0x00","0x19","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Node 1 to Node 2 cable missing"
"0xE0","0x00","0x1A","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Node 1 to Node 3 cable missing"
"0xE0","0x00","0x1B","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Node 2 to Node 3 cable missing"
"0xE0","0x00","0x1C","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Nodes could not merge"
"0xE0","0x00","0x1D","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","No 8 way SMP cable"
"0xE0","0x00","0x1E","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Primary North Bridge to PCI Host Bridge IB Link has failed"
"0xE0","0x00","0x1F","Chassis Number","Slot Number","Bus Number","Device ID (MSB)","Device ID (LSB)","Vendor ID (MSB)","Vendor ID (LSB)","R","R","R","0x00","Redundant PCI Host Bridge IB Link has failed"
"0xE0","0x00","0x00","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Device OK"
"0xE0","0x00","0x01","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Required ROM space not available"
"0xE0","0x00","0x02","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Required I/O Space not available"
"0xE0","0x00","0x03","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Required memory not available"
"0xE0","0x00","0x04","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Required memory below 1MB not available"
"0xE0","0x00","0x05","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","ROM checksum failed"
"0xE0","0x00","0x06","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","BIST failed"
"0xE0","0x00","0x07","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Planar device missing or disabled by user"
"0xE0","0x00","0x08","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","PCI device has an invalid PCI configuration space header"
"0xE0","0x00","0x09","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","FRU information for added PCI device"
"0xE0","0x00","0x0A","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","FRU information for removed PCI device"
"0xE0","0x00","0x0B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","A PCI device was added, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x0C","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","A PCI device was removed, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x0D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Requested resources not available"
"0xE0","0x00","0x13","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Planar video disabled due to add in video card"
"0xE0","0x00","0x14","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","FRU information for PCI device partially disabled "
"0xE0","0x00","0x15","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","A PCI device was partially disabled, PCI FRU information is stored in next log entry"
"0xE0","0x00","0x16","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","A 33Mhz device is installed on a 66Mhz bus, PCI device information is stored in next log entry"
"0xE0","0x00","0x17","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","FRU information, 33Mhz device installed on 66Mhz bus"
"0xE0","0x00","0x18","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Merge cable missing"
"0xE0","0x00","0x19","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Node 1 to Node 2 cable missing"
"0xE0","0x00","0x1A","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Node 1 to Node 3 cable missing"
"0xE0","0x00","0x1B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Node 2 to Node 3 cable missing"
"0xE0","0x00","0x1C","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Nodes could not merge"
"0xE0","0x00","0x1D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","No 8 way SMP cable"
"0xE0","0x00","0x1E","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Primary North Bridge to PCI Host Bridge IB Link has failed"
"0xE0","0x00","0x1F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","R","R","R","0x01","Redundant PCI Host Bridge IB Link has failed"
"0xE0","0x01","0x00","Chassis Number","Processor Number","R","R","R","R","R","R","R","R","0x00","Processor has failed BIST"
"0xE0","0x01","0x01","Chassis Number","Processor Number","R","R","R","R","R","R","R","R","0x00","Unable to apply processor microcode update"
"0xE0","0x01","0x02","Chassis Number","Processor Number","R","R","R","R","R","R","R","R","0x00","POST does not support current stepping level of processor"
"0xE0","0x01","0x03","Chassis Number","Processor Number","R","R","R","R","R","R","R","R","0x00","CPU mismatch detected"
"0xE0","0x01","0x04","Chassis Number","R","R","R","R","R","R","R","R","R","0x00","Invalid configuration of processor card."
"0xE0","0x02","0x00","Chassis Number","Memory Card","Memory DIMM","R","R","R","R","R","R","R","0x00","Uncorrectable memory error occurred"
"0xE0","0x02","0x01","Chassis Number","Memory Card","Memory DIMM","Failing Symbol","R","R","R","R","R","R","0x00","Correctable memory threshold occurred"
"0xE0","0x02","0x02","0x00","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x00","DIMM enabled"
"0xE0","0x02","0x02","0x01","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x00","DIMM disabled, failed ECC test"
"0xE0","0x02","0x02","0x02","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x00","DIMM disabled, failed POST/BIOS memory test"
"0xE0","0x02","0x02","0x03","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x00","DIMM disabled, non-supported memory device"
"0xE0","0x02","0x02","0x04","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x00","DIMM disabled, non-matching or missing DIMM(s)"
"0xE0","0x02","0x03","0x00","Chassis Number","Memory Card","R","R","R","R","R","R","R","0x00","Memory card enabled"
"0xE0","0x02","0x03","0x01","Chassis Number","Memory Card","R","R","R","R","R","R","R","0x00","Memory card disabled"
"0xE0","0x02","0x00","0x00","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM enabled"
"0xE0","0x02","0x00","0x01","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM disabled, failed ECC test"
"0xE0","0x02","0x00","0x02","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM disabled, failed POST/BIOS memory test"
"0xE0","0x02","0x00","0x03","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM disabled, non-supported memory device"
"0xE0","0x02","0x00","0x04","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM disabled, non-matching or missing DIMM(s)"
"0xE0","0x02","0x00","0x05","Chassis","Memory Card","Memory DIMM","R","R","R","R","R","R","0x01","DIMM disabled, multi-bit or multi-symbol error"
"0xE0","0x02","0x01","0x00","Chassis","Failed Channel","R","R","R","R","R","R","R","0x01","AMB Failure Detected on Channel X During Last Boot"
"0xE1","0x00","0x00","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","Unknown SERR/PERR detected on PCI bus"
"0xE1","0x00","0x01","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Address of special cycle DPE"
"0xE1","0x00","0x02","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: Master read parity error"
"0xE1","0x00","0x03","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Received target parity error"
"0xE1","0x00","0x04","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: Master write parity error"
"0xE1","0x00","0x05","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Device signaled SERR"
"0xE1","0x00","0x06","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: Slave signaled parity error"
"0xE1","0x00","0x07","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Signaled Target Abort"
"0xE1","0x00","0x08","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","BUS_CORRECTABLE: Additional Correctable ECC Error"
"0xE1","0x00","0x09","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Received Master Abort"
"0xE1","0x00","0x0A","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: Additional Uncorrectable ECC Error"
"0xE1","0x00","0x0B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Split Completion Discarded"
"0xE1","0x00","0x0C","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","BUS_CORRECTABLE: Correctable ECC Error"
"0xE1","0x00","0x0D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Unexpected Split Completion"
"0xE1","0x00","0x0E","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: Uncorrectable ECC Error"
"0xE1","0x00","0x0F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Received split completion error"
"0xE1","0x00","0x11","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Address of special cycle DPE"
"0xE1","0x00","0x12","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI-PCI bridge secondary error: Master read parity error"
"0xE1","0x00","0x13","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Received target parity error"
"0xE1","0x00","0x14","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI-PCI bridge secondary error: Master write parity error"
"0xE1","0x00","0x15","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Device Signaled SERR"
"0xE1","0x00","0x16","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI-PCI bridge secondary error: Slave Signaled Parity Error"
"0xE1","0x00","0x17","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Signaled Target Abort"
"0xE1","0x00","0x18","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","BUS_CORRECTABLE: PCI-PCI bridge secondary error: Additional Correctable ECC Error"
"0xE1","0x00","0x19","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Received Master Abort"
"0xE1","0x00","0x1A","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI-PCI bridge secondary error: Additional Uncorrectable ECC Error"
"0xE1","0x00","0x1B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Split Completion Discarded"
"0xE1","0x00","0x1C","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","BUS_CORRECTABLE: PCI-PCI bridge secondary error: Correctable ECC Error"
"0xE1","0x00","0x1D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Unexpected Split Completion"
"0xE1","0x00","0x1E","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI-PCI bridge secondary error: Uncorrectable ECC Error"
"0xE1","0x00","0x1F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI-PCI bridge secondary error: Received split completion error"
"0xE1","0x00","0x20","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","BUS_CORRECTABLE: PCI ECC Error (Corrected)"
"0xE1","0x00","0x21","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI Bus Address Parity Error"
"0xE1","0x00","0x22","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI Bus Data Parity Error"
"0xE1","0x00","0x23","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: SERR# Asserted"
"0xE1","0x00","0x24","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PERR Received by Calgary on a PCIX Split Completion"
"0xE1","0x00","0x25","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Invalid Address"
"0xE1","0x00","0x27","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: TCE Extent Error"
"0xE1","0x00","0x29","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Page Fault"
"0xE1","0x00","0x2B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Unauthorized Access"
"0xE1","0x00","0x2D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Parity Error in DMA Read Data Buffer"
"0xE1","0x00","0x2F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI Bus Time Out"
"0xE1","0x00","0x31","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: DMA Delayed Read Timeout"
"0xE1","0x00","0x33","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Internal Error on PCIX Split Completion"
"0xE1","0x00","0x35","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: DMA Read Reply (RIO) Timeout"
"0xE1","0x00","0x37","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Internal RAM Error on DMA Write"
"0xE1","0x00","0x39","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: MVE Valid Bit Off"
"0xE1","0x00","0x3B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: MVE Index Invalid"
"0xE1","0x00","0x40","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: ECC Error (Corrected)"
"0xE1","0x00","0x41","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: SERR# Detected"
"0xE1","0x00","0x42","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI Bus Data Parity Error"
"0xE1","0x00","0x43","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: No DEVSEL#"
"0xE1","0x00","0x45","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Bus Time Out"
"0xE1","0x00","0x47","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Retry Count Expired"
"0xE1","0x00","0x49","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Target-Abort"
"0xE1","0x00","0x4B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Invalid Size"
"0xE1","0x00","0x4D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Access Not Enabled"
"0xE1","0x00","0x4F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Internal RAM Error on MMIO Store"
"0xE1","0x00","0x51","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Split Response Received"
"0xE1","0x00","0x53","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCIX Split Completion Error Status Received"
"0xE1","0x00","0x55","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Unexpected PCIX Split Completion Received"
"0xE1","0x00","0x57","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCIX Split Completion Timeout"
"0xE1","0x00","0x59","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Recoverable Error Summary Bit"
"0xE1","0x00","0x5B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: CSR Error Summary Bit"
"0xE1","0x00","0x5D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Internal RAM Error on MMIO Load"
"0xE1","0x00","0x61","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Bad Command"
"0xE1","0x00","0x63","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Length Field Invalid"
"0xE1","0x00","0x65","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Load Greater Than 8 & No Write Buffer Enabled"
"0xE1","0x00","0x67","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCIX Discontiguous Byte Enable Error"
"0xE1","0x00","0x69","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: 4K Address Boundary Crossing Error"
"0xE1","0x00","0x6B","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Store Wrap State Machine Check"
"0xE1","0x00","0x6D","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Target State Machine Check"
"0xE1","0x00","0x6F","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Invalid Transaction PM/DW"
"0xE1","0x00","0x71","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Invalid Transaction PM/DR"
"0xE1","0x00","0x73","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: Invalid Transaction PS/DW"
"0xE1","0x00","0x75","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: DMA Write Command FIFO Parity Error"
"0xE1","0x00","0x76","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PERR: PCI Secondary Status Register Dump"
"0xE1","0x00","0x77","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","SERR: PCI Secondary Status Register Dump"
"0xE1","0x00","0x81","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x00","PCI-to-PCI Bridge Discard Timer Error"
"0xE1","0x00","0x01","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x01","SERR detected on PCI bus"
"0xE1","0x00","0x02","Chassis Number","Slot Number","Bus Number","Device ID (LSB)","Device ID (MSB)","Vendor ID (LSB)","Vendor ID (MSB)","Status Register (LSB)","Status Register (MSB)","DevFun Number","0x01","PERR detected on PCI bus"
"0xE1","0x01","0x00","R","R","Bank (LSB)","Bank (MSB)","Apic ID (LSB)","Apic ID (MSB)","CK4(LSB)","CK4","CK4","CK4(MSB)","0x00","Processor Error Information Data A"
"0xE1","0x01","0x01","R","R","Address high (LSB)","Address high","Address high","Address high (MSB)","Address low (LSB)","Address low ","Address low ","Address low (MSB)","0x00","Processor Error Information Data B1"
"0xE1","0x01","0x02","R","R","Timestamp high (LSB)","Timestamp high","Timestamp high","Timestamp high (MSB)","Timestamp Low (LSB)","Timestamp low","Timestamp low","Timestamp low (MSB)","0x00","Processor Error Information Data B2"
"0xE1","0x01","0x03","R","R","MCA status register high (LSB)","MCA status register high","MCA status register high","MCA status register high (MSB)","MCA status register low (LSB)","MCA status register low","MCA status register low","MCA status register low (MSB)","0x00","Processor Error Information Data C"
"0xE1","0x01","0x04","Chassis","0x00","Processor ID","R","R","R","R","R","R","R","0x00","Processor recoverable error"
"0xE1","0x01","0x04","Chassis","0x01","Processor ID","R","R","R","R","R","R","R","0x00","Processor unrecoverable error"
"0xE1","0x02","0x00","0x00","Failed Row","Spare Row","R","R","R","R","R","R","R","0x00","Memory sparing event, start 1"
"0xE1","0x02","0x00","0x02","Failed Row","Spare Row","R","R","R","R","R","R","R","0x00","Memory sparing event, done 1"
"0xE1","0x02","0x00","0x01","Failed Row 1","Failed Row 2","Spare Row 1","Spare Row 2","R","R","R","R","R","0x00","Memory sparing event, start 2"
"0xE1","0x02","0x00","0x03","Failed Row 1","Failed Row 2","Spare Row 1","Spare Row 2","R","R","R","R","R","0x00","Memory sparing event, done 2"
"0xE1","0x02","0x01","Failed Port","Spare Port","R","R","R","R","R","R","R","R","0x00","Memory mirroring failover occurred"
"0xE1","0x02","0x00","0x00","R","R","R","R","R","R","R","R","R","0x01","Memory sparing event, start 1"
"0xE1","0x02","0x00","0x02","R","R","R","R","R","R","R","R","R","0x01","Memory sparing event, done 1"
"0xE1","0x04","0x00","0x00","FSB FERR/NERR Register","FSB FERR/NERR Register","Chassis Number","R","R","R","R","R","R","0x00","FSB A Fatal"
"0xE1","0x04","0x00","0x01","FSB FERR/NERR Register","FSB FERR/NERR Register","Chassis Number","R","R","R","R","R","R","0x00","FSB A Nonfatal"
"0xE1","0x04","0x00","0x02","FSB FERR/NERR Register","FSB FERR/NERR Register","Chassis Number","R","R","R","R","R","R","0x00","FSB B Fatal"
"0xE1","0x04","0x00","0x03","FSB FERR/NERR Register","FSB FERR/NERR Register","Chassis Number","R","R","R","R","R","R","0x00","FSB B Nonfatal"
"0xE1","0x05","0x00","0x02","Hi FERR or NERR Register","R","R","R","R","R","R","R","R","0x00","Lindenhurst Chipset Event: Hi Fatal"
"0xE1","0x05","0x00","0x03","Hi FERR or NERR Register","R","R","R","R","R","R","R","R","0x00","Lindenhurst Chipset Event: Hi Nonfatal"
"0xE1","0x05","0x01","0x02","Status Register Contents","R","R","R","R","R","R","R","R","0x00","Fatal internal north bridge error"
"0xE1","0x05","0x01","0x03","Status Register Contents","R","R","R","R","R","R","R","R","0x00","Nonfatal internal north bridge error"
"0xE1","0x05","0x01","0x04","Bus","Device","Function Number","R","R","R","R","R","R","0x00","Link Degrade Event"
"0xE1","0x05","0x01","0x05","R","R","R","R","R","R","R","R","R","0x00","Spurious Memory Event"
"0xE2","0x00","Register ID","R","First Fire Bit (0xFF=N/A)","Register Data (LSB)","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data (MSB)","0x00","PCI Industry Standard Register Dump"
"0xE2","0x01","Register ID","R","First Fire Bit (0xFF if N/A)","Register Data (LSB)","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data (MSB)","0x00","PCI-X Industry Standard Register Dump"
"0xE2","0x02","Register ID","R","First Fire Bit (0xFF if N/A)","Register Data (LSB)","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data","Register Data (MSB)","0x00","PCI Express Industry Standard Register Dump"
"0xE3","Platform ID","Register ID","R","R","R","R","R","R","Register Data (LSB)","Register Data","Register Data","Register Data (MSB)","0x00","RAW Hex Dump"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x00","0x00","R","R","R","0x00","PCI Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x01","0x00","R","R","R","0x00","Processor Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x02","0x00","R","R","R","0x00","Memory Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x00","R","R","R","0x00"," Scalability Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x07","R","R","0x00","Merge Failure - BIOS version is newer than secondary server BIOS"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x08","R","R","0x00","Merge Failure - BIOS version is older than secondary server BIOS"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x09","R","R","0x00","Merge Failure - Primary server booted standalone"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x0A","R","R","0x00","Merge Failure - Communication error occurred with secondary server"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x0B","R","R","0x00","Merge Failure - Timed out waiting for secondary server"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x10","R","R","0x00","Merge Failure - No path through partition"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x11","Expected Chassis Count","R","0x00","Merge Information - Expected chassis count"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x12","Actual Chassis Count","R","0x00","Merge Information - Actual chassis count"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x19","R","R","0x00","Merge Failure - No secondary servers found to merge"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x34","R","R","0x00","Merge Failure - Primary server booted standalone"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x35","R","R","0x00","Merge Failure - Communication error occurred with primary server"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x36","R","R","0x00","Merge Failure - Secondary server booted standalone"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x41","R","R","0x00","Merge Failure - Timeout occurred waiting for primary server"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x46","R","R","0x00","Merge Failure - BIOS version is newer than primary server BIOS"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x47","R","R","0x00","Merge Failure - BIOS version is older than primary server BIOS"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x52","R","R","0x00","Merge Failure - Scalability hardware not detected"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x53","R","R","0x00","Merge Failure - No partition descriptor found"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x54","R","R","0x00","Merge Failure - Error Reading partition descriptor"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x55","R","R","0x00","Merge Failure - Error Reading system UUID"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x56","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x57","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x58","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x59","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x5A","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x5B","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x03","0x01","0x5C","R","R","0x00","Merge Failure [Byte 13 value]"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x04","0x00","R","R","R","0x00","Bus PCI Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x05","0x00","R","R","R","0x00","Chipset Event/Error Occurred. Next non-timestamped OEM SEL entry will contain details of the specific PCI event/error"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x06","0x01","PostVersion","BMCVersion","R","0x00","Incompatible BIOS-BMC Power Executive support"
"0xC0","XX","XX","XX","XX","XX","XX","XX","0x06","0x02","R","R","R","0x00","Boot denied due to power limitations"