PICMG extension 5(UTCA, MicroTCA) is not detected as valid extension.
The following patch fixes that at one place. In the second place the board type
is detected in a similar way, but it isn't clear if a patch is needed there, too.
The LED state bits are not mutually exclusive. Bit [0] says LEDs can be
controlled locally and the state bit [1] says wheter the default local
settings or the override settings are used. This means that both bits can be
set at the same time.
Bit [2], the lamp test, indicates wether the test is in progress and logically
works the same as [1].
If bit [0] is not set then bit [1] and [2] has no meaning.
Signed-off-by: Jens Nyberg <jens.nyberg@ericsson.com>
'picmg policy set' command uses too restrictive input values check
which allow setting/clearing only the Activation Locked Bit (#0).
This patch fixes the check to allow setting/clearing Deactivation
Locked Bit (#1) as well.