mirror of
https://github.com/MicrosoftDocs/windows-itpro-docs.git
synced 2025-06-23 06:13:41 +00:00
USMT Refresh 20
This commit is contained in:
@ -102,8 +102,8 @@ System environment variables are necessary in the scenarios outlined in the foll
|
||||
|
||||
|Variable|Value|Scenario|
|
||||
|--- |--- |--- |
|
||||
|**USMT_WORKING_DIR**|Full path to a working directory|Required when USMT binaries are located on read-only media, which doesn't support the creation of log files or temporary storage. To set the system environment variable, at a command prompt type the following command: <br><br> `Set USMT_WORKING_DIR=<path to working directory>`|
|
||||
|**MIG_OFFLINE_PLATFORM_ARCH**|32 or 64|While operating offline, this environment variable defines the architecture of the offline system, if the system doesn't match the WinPE and `ScanState.exe` architecture. This environment variable enables the 32-bit ScanState application to gather data from a computer with 64-bit architecture, or the 64-bit ScanState application to gather data from a computer with 32-bit architecture. Specifying the architecture is required when auto-detection of the offline architecture doesn't function properly. For example, to set this system environment variable for a 32-bit architecture, at a command prompt type the following command: <br><br> `Set MIG_OFFLINE_PLATFORM_ARCH=32`|
|
||||
|**USMT_WORKING_DIR**|Full path to a working directory|Required when USMT binaries are located on read-only media, which doesn't support the creation of log files or temporary storage. To set the system environment variable, at a command prompt type the following command:<br><br> `Set USMT_WORKING_DIR=<path to working directory>`|
|
||||
|**MIG_OFFLINE_PLATFORM_ARCH**|32 or 64|While operating offline, this environment variable defines the architecture of the offline system, if the system doesn't match the WinPE and `ScanState.exe` architecture. This environment variable enables the 32-bit ScanState application to gather data from a computer with 64-bit architecture, or the 64-bit ScanState application to gather data from a computer with 32-bit architecture. Specifying the architecture is required when auto-detection of the offline architecture doesn't function properly. For example, to set this system environment variable for a 32-bit architecture, at a command prompt type the following command:<br><br> `Set MIG_OFFLINE_PLATFORM_ARCH=32`|
|
||||
|
||||
## Offline.xml elements
|
||||
|
||||
|
Reference in New Issue
Block a user