diff --git a/windows/deployment/update/update-compliance-configuration-script.md b/windows/deployment/update/update-compliance-configuration-script.md index 3bd9ab7dd2..3a3ce84428 100644 --- a/windows/deployment/update/update-compliance-configuration-script.md +++ b/windows/deployment/update/update-compliance-configuration-script.md @@ -55,32 +55,31 @@ Open `RunConfig.bat` and configure the following (assuming a first-run, with `ru |Error |Description | |---------|---------| -| 27 | Not system account. | -| 37 | Unexpected exception when collecting logs| | 1 | General unexpected error| | 6 | Invalid CommercialID| -| 48 | CommercialID is not a GUID| | 8 | Couldn't create registry key path to setup CommercialID| | 9 | Couldn't write CommercialID at registry key path| -| 53 | There are conflicting CommercialID values.| | 11 | Unexpected result when setting up CommercialID.| -| 62 | AllowTelemetry registry key is not of the correct type REG_DWORD| -| 63 | AllowTelemetry is not set to the appropriate value and it could not be set by the script.| -| 64 | AllowTelemetry is not of the correct type REG_DWORD.| -| 99 | Device is not Windows 10.| -| 40 | Unexpected exception when checking and setting telemetry.| | 12 | CheckVortexConnectivity failed, check Log output for more information.| | 12 | Unexpected failure when running CheckVortexConnectivity.| -| 66 | Failed to verify UTC connectivity and recent uploads.| -| 67 | Unexpected failure when verifying UTC CSP.| +| 16 | Reboot is pending on device, restart device and restart script.| +| 17 | Unexpected exception in CheckRebootRequired.| +| 27 | Not system account. | +| 30 | Unable to disable Enterprise Auth Proxy. This registry value must be 0 for UTC to operate in an authenticated proxy environment.| +| 34 | Unexpected exception when attempting to check Proxy settings.| +| 35 | Unexpected exception when checking User Proxy.| +| 37 | Unexpected exception when collecting logs| +| 40 | Unexpected exception when checking and setting telemetry.| | 41 | Unable to impersonate logged-on user.| | 42 | Unexpected exception when attempting to impersonate logged-on user.| | 43 | Unexpected exception when attempting to impersonate logged-on user.| -| 16 | Reboot is pending on device, restart device and restart script.| -| 17 | Unexpected exception in CheckRebootRequired.| | 44 | Error when running CheckDiagTrack service.| | 45 | DiagTrack.dll not found.| +| 48 | CommercialID is not a GUID| | 50 | DiagTrack service not running.| +| 51 | Unexpected exception when attempting to run Census.exe| +| 52 | Could not find Census.exe| +| 53 | There are conflicting CommercialID values.| | 54 | Microsoft Account Sign In Assistant (MSA) Service disabled.| | 55 | Failed to create new registry path for SetDeviceNameOptIn| | 56 | Failed to create property for SetDeviceNameOptIn at registry path| @@ -89,12 +88,13 @@ Open `RunConfig.bat` and configure the following (assuming a first-run, with `ru | 59 | Failed to delete LastPersistedEventTimeOrFirstBoot property at registry path when attempting to clean up OneSettings.| | 60 | Failed to delete registry key when attempting to clean up OneSettings.| | 61 | Unexpected exception when attempting to clean up OneSettings.| -| 52 | Could not find Census.exe| -| 51 | Unexpected exception when attempting to run Census.exe| -| 34 | Unexpected exception when attempting to check Proxy settings.| -| 30 | Unable to disable Enterprise Auth Proxy. This registry value must be 0 for UTC to operate in an authenticated proxy environment.| -| 35 | Unexpected exception when checking User Proxy.| +| 62 | AllowTelemetry registry key is not of the correct type REG_DWORD| +| 63 | AllowTelemetry is not set to the appropriate value and it could not be set by the script.| +| 64 | AllowTelemetry is not of the correct type REG_DWORD.| +| 66 | Failed to verify UTC connectivity and recent uploads.| +| 67 | Unexpected failure when verifying UTC CSP.| | 91 | Failed to create new registry path for EnableAllowUCProcessing| | 92 | Failed to create property for EnableAllowUCProcessing at registry path| | 93 | Failed to update value for EnableAllowUCProcessing| | 94 | Unexpected exception in EnableAllowUCProcessing| +| 99 | Device is not Windows 10.|