@ -22,45 +22,14 @@ Using a room control system with your Surface Hub involves connecting room contr
|
||||
|
||||
To connect to a room control system control panel, you don't need to configure any terminal settings on the Surface Hub. If you want to connect a PC or laptop to your Surface Hub and send serial commands from the Surface Hub, you can use a terminal emulator program like Tera Term or PuTTY.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="50%" />
|
||||
<col width="50%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Setting</th>
|
||||
<th align="left">Value</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Baud rate</p></td>
|
||||
<td align="left"><p>115200</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Data bits</p></td>
|
||||
<td align="left"><p>8</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Stop bits</p></td>
|
||||
<td align="left"><p>1</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Parity</p></td>
|
||||
<td align="left"><p>none</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Flow control</p></td>
|
||||
<td align="left"><p>none</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Line feed</p></td>
|
||||
<td align="left"><p>every carriage return</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
|
||||
| Setting | Value |
|
||||
| --- | --- |
|
||||
| Baud rate | 115200 |
|
||||
| Data bits | 8 |
|
||||
| Stop bits | 1 |
|
||||
| Parity | none |
|
||||
| Flow control | none |
|
||||
| Line feed | every carriage return |
|
||||
|
||||
|
||||
## Wiring diagram
|
||||
@ -77,153 +46,41 @@ Room control systems use common meeting-room scenarios for commands. Commands or
|
||||
|
||||
The following command modifiers are available. Commands terminate with a new line character (/n). Responses can come at any time in response to state changes not triggered directly by a management port command.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="50%" />
|
||||
<col width="50%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Modifier</th>
|
||||
<th align="left">Result</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>+</p></td>
|
||||
<td align="left"><p>Increment a value</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>-</p></td>
|
||||
<td align="left"><p>Decrease a value</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>=</p></td>
|
||||
<td align="left"><p>Set a discrete value</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>?</p></td>
|
||||
<td align="left"><p>Queries for a current value</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
|
||||
| Modifier | Result |
|
||||
| --- | --- |
|
||||
| + | Increment a value |
|
||||
| - | Decrease a value |
|
||||
| = | Set a discrete value |
|
||||
| ? | Queries for a current value |
|
||||
|
||||
|
||||
## Power
|
||||
|
||||
Surface Hub can be in one of these power states.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">State</th>
|
||||
<th align="left">Energy Star state</th>
|
||||
<th align="left">Description</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>0</p></td>
|
||||
<td align="left"><p>S5</p></td>
|
||||
<td align="left"><p>Off</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>1</p></td>
|
||||
<td align="left"><p>-</p></td>
|
||||
<td align="left"><p>Power up (indeterminate)</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>2</p></td>
|
||||
<td align="left"><p>S3</p></td>
|
||||
<td align="left"><p>Sleep</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>3</p></td>
|
||||
<td align="left"><p>S0</p></td>
|
||||
<td align="left"><p>Resting</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>4</p></td>
|
||||
<td align="left"><p>S0</p></td>
|
||||
<td align="left"><p>Ambient</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>5</p></td>
|
||||
<td align="left"><p>S0</p></td>
|
||||
<td align="left"><p>Ready</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| State | Energy Star state| Description |
|
||||
| --- | --- | --- |
|
||||
| 0 | S5 | Off |
|
||||
| 1 | - | Power up (indeterminate) |
|
||||
| 2 | S3 | Sleep |
|
||||
| 5 | S0 | Ready |
|
||||
|
||||
|
||||
In Replacement PC mode, the power states are only Ready and Off and only change the display. The management port can't be used to power on the replacement PC.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">State</th>
|
||||
<th align="left">Energy Star state</th>
|
||||
<th align="left">Description</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>0</p></td>
|
||||
<td align="left"><p>S5</p></td>
|
||||
<td align="left"><p>Off</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>5</p></td>
|
||||
<td align="left"><p>S0</p></td>
|
||||
<td align="left"><p>Ready</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| State | Energy Star state| Description |
|
||||
| --- | --- | --- |
|
||||
| 0 | S5 | Off |
|
||||
| 5 | S0 | Ready |
|
||||
|
||||
For a control device, anything other than 5 / Ready should be considered off. Each PowerOn command results in two state changes and reponses.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Command</th>
|
||||
<th align="left">State change</th>
|
||||
<th align="left">Response</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>PowerOn</p></td>
|
||||
<td align="left"><p>Device turns on (display + PC).</p><p>PC service notifies SMC that the PC is ready.</p></td>
|
||||
<td align="left"><p>Power=0</p><p>Power=5</p></td>
|
||||
</tr>
|
||||
| Command | State change| Response |
|
||||
| --- | --- | --- |
|
||||
| PowerOn | Device turns on (display + PC).</br></br>PC service notifies SMC that the PC is ready. | Power=0</br></br>Power=5 |
|
||||
| PowerOff | Device transitions to ambient state (PC on, display dim). | Power=0 |
|
||||
| Power? | SMC reports the last-known power state. | Power=<#> |
|
||||
|
||||
<tr class="even">
|
||||
<td align="left"><p>PowerOff</p></td>
|
||||
<td align="left"><p>Device transitions to ambient state (PC on, display dim).</p></td>
|
||||
<td align="left"><p>Power=0</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Power?</p></td>
|
||||
<td align="left"><p>SMC reports the last-known power state.</p></td>
|
||||
<td align="left"><p>Power=<#></p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
|
||||
|
||||
## Brightness
|
||||
@ -232,34 +89,10 @@ The current brightness level is a range from 0 to 100.
|
||||
|
||||
Changes to brightness levels can be sent by a room control system, or other system.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Command</th>
|
||||
<th align="left">State change</th>
|
||||
<th align="left">Response</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Brightness+</p></td>
|
||||
<td align="left"><p>System management controller (SMC) sends the brightness up command.</p>
|
||||
<p>PC service on the room control system notifies SMC of new brightness level.</p></td>
|
||||
<td align="left"><p>Brightness = 51</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Brightness-</p></td>
|
||||
<td align="left"><p>SMC sends the brightness down command.</p>
|
||||
<p>PC service notifies SMC of new brightness level.</p></td>
|
||||
<td align="left"><p>Brightness = 50</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| Command | State change |Response |
|
||||
| --- | --- | --- |
|
||||
| Brightness+ | System management controller (SMC) sends the brightness up command.</br></br>PC service on the room control system notifies SMC of new brightness level. | Brightness = 51 |
|
||||
| Brightness- | | SMC sends the brightness down command.</br></br>PC service notifies SMC of new brightness level. | Brightness = 50 |
|
||||
|
||||
## Volume
|
||||
|
||||
@ -270,34 +103,11 @@ Changes to volume levels can be sent by a room control system, or other system.
|
||||
>[!NOTE]
|
||||
>The Volume command will only control the volume for embedded or Replacement PC mode, not from [Guest sources](connect-and-display-with-surface-hub.md).
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Command</th>
|
||||
<th align="left">State change</th>
|
||||
<th align="left">Response</br>(On in [Replacement PC mode](connect-and-display-with-surface-hub.md#replacement-pc-mode))</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Volume+</p></td>
|
||||
<td align="left"><p>SMC sends the volume up command.</p>
|
||||
<p>PC service notifies SMC of new volume level.</p></td>
|
||||
<td align="left"><p>Volume = 51</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Volume-</p></td>
|
||||
<td align="left"><p>SMC sends the volume down command.</p>
|
||||
<p>PC service notifies SMC of new volume level.</p></td>
|
||||
<td align="left"><p>Volume = 50</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| Command | State change | Response</br>(On in [Replacement PC mode](connect-and-display-with-surface-hub.md#replacement-pc-mode)) |
|
||||
| --- | --- | --- |
|
||||
| Volume+ | SMC sends the volume up command.</br></br>>PC service notifies SMC of new volume level. | Volume = 51 |
|
||||
| Volume- | SMC sends the volume down command.</br></br>>PC service notifies SMC of new volume level. | Volume = 50 |
|
||||
|
||||
|
||||
|
||||
|
||||
@ -305,28 +115,10 @@ Changes to volume levels can be sent by a room control system, or other system.
|
||||
|
||||
Audio can be muted.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Command</th>
|
||||
<th align="left">State change</th>
|
||||
<th align="left">Response</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>AudioMute+</p></td>
|
||||
<td align="left"><p>SMC sends the audio mute command.</p>
|
||||
<p>PC service notifies SMC that audio is muted.</p></td>
|
||||
<td align="left"><p>none</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| Command | State change | Response |
|
||||
| --- | --- | --- |
|
||||
| AudioMute+ | SMC sends the audio mute command.</br></br>>PC service notifies SMC that audio is muted. | none |
|
||||
|
||||
|
||||
|
||||
|
||||
@ -334,116 +126,36 @@ Audio can be muted.
|
||||
|
||||
Several display sources can be used.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="50%" />
|
||||
<col width="50%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">State</th>
|
||||
<th align="left">Description</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>0</p></td>
|
||||
<td align="left"><p>Onboard PC</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>1</p></td>
|
||||
<td align="left"><p>DisplayPort</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>2</p></td>
|
||||
<td align="left"><p>HDMI</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>3</p></td>
|
||||
<td align="left"><p>VGA</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| State | Description |
|
||||
| --- | --- |
|
||||
| 0 | Onboard PC |
|
||||
| 1 | DisplayPort |
|
||||
| 2 | HDMI |
|
||||
| 3 | VGA |
|
||||
|
||||
|
||||
|
||||
|
||||
Changes to display source can be sent by a room control system, or other system.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
<col width="33%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Command</th>
|
||||
<th align="left">State change</th>
|
||||
<th align="left">Response</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Source=#</p></td>
|
||||
<td align="left"><p>SMC changes to the desired source.</p>
|
||||
<p>PC service notifies SMC that the display source has switched.</p></td>
|
||||
<td align="left"><p>Source=<#></p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Source+</p></td>
|
||||
<td align="left"><p>SMC cycles to the next active input source.</p>
|
||||
<p>PC service notifies SMC of the current input source.</p></td>
|
||||
<td align="left"><p>Source=<#></p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Source-</p></td>
|
||||
<td align="left"><p>SMC cycles to the previous active input source.</p>
|
||||
<p>PC service notifies SMC of the current input source.</p></td>
|
||||
<td align="left"><p>Source=<#></p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Source?</p></td>
|
||||
<td align="left"><p>SMC queries PC service for the active input source.</p>
|
||||
<p>PC service notifies SMC of the current in;put source.</p></td>
|
||||
<td align="left"><p>Source=<#></p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| Command | State change | Response |
|
||||
| --- | --- | --- |
|
||||
| Source=# | SMC changes to the desired source.</br></br>>PC service notifies SMC that the display source has switched. | Source=<#> |
|
||||
| Source+ | SMC cycles to the next active input source.</br></br>>PC service notifies SMC of the current input source. | Source=<#> |
|
||||
| Source- | SMC cycles to the previous active input source.</br></br>>PC service notifies SMC of the current input source. | Source=<#> |
|
||||
| Source? | SMC queries PC service for the active input source.</br></br>>PC service notifies SMC of the current in;put source. | Source=<#> |
|
||||
|
||||
## Errors
|
||||
|
||||
Errors are returned following the format in this table.
|
||||
|
||||
<table>
|
||||
<colgroup>
|
||||
<col width="50%" />
|
||||
<col width="50%" />
|
||||
</colgroup>
|
||||
<thead>
|
||||
<tr class="header">
|
||||
<th align="left">Error</th>
|
||||
<th align="left">Notes</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Error: Unknown command '<input>'.</p></td>
|
||||
<td align="left"><p>The instruction contains an unknown initial command. For example, "VOL+" would be invalid and return " Error: Unknown command 'VOL'".</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Error: Unknown operator '<input>'.</p></td>
|
||||
<td align="left"><p>The instruction contains an unknown operator. For example, "Volume!" would be invalid and return " Error: Unknown operator '!'".</p></td>
|
||||
</tr>
|
||||
<tr class="odd">
|
||||
<td align="left"><p>Error: Unknown parameter '<input>'.</p></td>
|
||||
<td align="left"><p>The instruction contains an unknown parameter. For example, "Volume=abc" would be invalid and return " Error: Unknown parameter 'abc'".</p></td>
|
||||
</tr>
|
||||
<tr class="even">
|
||||
<td align="left"><p>Error: Command not available when off '<input>'.</p></td>
|
||||
<td align="left"><p>When the Surface Hub is off, commands other than Power return this error. For example, "Volume+" would be invalid and return " Error: Command not available when off 'Volume'".</p></td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
| Error | Notes |
|
||||
| --- | --- |
|
||||
| Error: Unknown command '<input>'. | The instruction contains an unknown initial command. For example, "VOL+" would be invalid and return " Error: Unknown command 'VOL'". |
|
||||
| Error: Unknown operator '<input>'. | The instruction contains an unknown operator. For example, "Volume!" would be invalid and return " Error: Unknown operator '!'". |
|
||||
| Error: Unknown parameter '<input>'. | The instruction contains an unknown parameter. For example, "Volume=abc" would be invalid and return " Error: Unknown parameter 'abc'". |
|
||||
| Error: Command not available when off '<input>'. | When the Surface Hub is off, commands other than Power return this error. For example, "Volume+" would be invalid and return " Error: Command not available when off 'Volume'". |
|
||||
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue