mirror of
https://github.com/MicrosoftDocs/windows-itpro-docs.git
synced 2025-06-15 18:33:43 +00:00
acrolinx
This commit is contained in:
@ -66,8 +66,8 @@ Add these exclusions to UWF:
|
||||
```
|
||||
|
||||
> [!NOTE]
|
||||
> Windows 10 Enterprise does not include System Center Endpoint Protection. You can purchase licenses and install System Center Endpoint Protection independently.
|
||||
> Windows 10 Enterprise doesn't include System Center Endpoint Protection. You can purchase licenses and install System Center Endpoint Protection independently.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Service UWF-protected devices](service-uwf-protected-devices.md)
|
||||
|
@ -35,7 +35,7 @@ echo Restarting system
|
||||
goto UPDATE_EXIT
|
||||
```
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Service UWF-protected devices](service-uwf-protected-devices.md)
|
||||
- [UWF master servicing script](uwf-master-servicing-script.md)
|
||||
|
@ -62,7 +62,7 @@ When Windows update servicing is finished, the system will disable UWF servicing
|
||||
> [!NOTE]
|
||||
> If Windows updates cannot be installed or return an error, servicing will be disabled and the system will restart with UWF-protection re-enabled and all file and registry exclusions restored to their original pre-servicing state.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
- [UWF master servicing script](uwf-master-servicing-script.md)
|
||||
|
@ -45,7 +45,7 @@ You can use the [UWF_Volume.AddExclusion](uwf-volumeaddexclusion.md) and [UWF_Vo
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter WMI provider reference](uwf-wmi-provider-reference.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -45,7 +45,7 @@ You can use the [UWF_Volume.AddExclusion](uwf-volumeaddexclusion.md) and [UWF_Vo
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter WMI provider reference](uwf-wmi-provider-reference.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -163,7 +163,7 @@ Display-UWFState
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter WMI provider reference](uwf-wmi-provider-reference.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -37,7 +37,7 @@ You must use an administrator account to disable UWF.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Filter](uwf-filter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -60,7 +60,7 @@ After you run `uwfmgr filter disable`, restart the computer and enter the servin
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Filter](uwf-filter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -41,7 +41,7 @@ If the overlay becomes full while the system is performing a large amount of wri
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Filter](uwf-filter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -81,7 +81,7 @@ shutdown -r -t 5
|
||||
EXIT /B
|
||||
```
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
[Service UWF-protected devices](service-uwf-protected-devices.md)
|
||||
|
||||
|
@ -152,7 +152,7 @@ Set-OverlayType $DiskMode
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
[Unified Write Filter WMI provider reference](uwf-wmi-provider-reference.md)
|
||||
|
||||
|
@ -49,7 +49,7 @@ If the overlay type is RAM-based, your device must meet the following requiremen
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_OverlayConfig](uwf-overlayconfig.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -51,7 +51,7 @@ Before you can change the overlay type to RAM-based, your device must meet the f
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_OverlayConfig](uwf-overlayconfig.md)
|
||||
- [Overlay for Unified Write Filter (UWF)](uwfoverlay.md)
|
||||
|
@ -45,7 +45,7 @@ For more information about specific limitations and conditions when using the **
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter WMI provider reference](uwf-wmi-provider-reference.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -61,7 +61,7 @@ You should also be aware of the following items when you use the **GetOverlayFil
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Overlay](uwf-overlay.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -45,7 +45,7 @@ The critical threshold must be higher than the warning threshold.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Overlay](uwf-overlay.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -45,7 +45,7 @@ The warning threshold must be lower than the critical threshold.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Overlay](uwf-overlay.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -264,6 +264,6 @@ Clear-RegistryExclusions
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -52,7 +52,7 @@ You must restart the device before the registry key is excluded from UWF filteri
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -44,7 +44,7 @@ You must use an administrator account to change any properties or call any metho
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -46,7 +46,7 @@ You must use an administrator account to change any properties or call any metho
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -38,7 +38,7 @@ Returns an HRESULT value that indicates [WMI status](/windows/win32/wmisdk/wmi-n
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ If this method does not find any registry keys in the registry key exclusion lis
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ You must restart the device before the registry key is excluded from UWF filteri
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_RegistryFilter](uwf-registryfilter.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -44,7 +44,7 @@ Do not select **UwfServicingScr** as the screen saver and then click **Preview**
|
||||
|
||||
The next time the device enters UWF servicing mode, the UwfServicingScr.scr screen saver will use the custom settings.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
[Service UWF-protected devices](service-uwf-protected-devices.md)
|
||||
|
||||
|
@ -94,6 +94,6 @@ if ($nextSession) {
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -37,7 +37,7 @@ When this method is called, the system will leave servicing mode in the next ses
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Servicing](uwf-servicing.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -37,7 +37,7 @@ When this method is called, the system will enter servicing mode in the next ses
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Servicing](uwf-servicing.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -47,7 +47,7 @@ This method does not disable or enable Unified Write Filter (UWF). If you call t
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Servicing](uwf-servicing.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -2,7 +2,7 @@
|
||||
title: Unified Write Filter (UWF) feature (uwf-turnonuwf)
|
||||
description: Unified Write Filter (UWF) feature (uwf-turnonuwf)
|
||||
ms.date: 05/20/2024
|
||||
ms.topic: article
|
||||
ms.topic: reference
|
||||
ms.custom: RS5
|
||||
---
|
||||
|
||||
@ -137,7 +137,7 @@ All configuration settings for UWF are stored in the registry. UWF automatically
|
||||
|
||||
UWF maintains configuration settings in the registry for the current session and for the next session after a device restart. Static configuration changes do not take effect until after a device restart, and these changes are saved in the registry entries for the next session. Dynamic configuration changes occur immediately and persist after a device restart.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
[Unified Write Filter]( index.md)
|
||||
|
||||
|
@ -306,6 +306,6 @@ Get-FileExclusions "C:"
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -50,7 +50,7 @@ However, you can exclude subdirectories and files under these items.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -41,7 +41,7 @@ You must use an administrator account to change any properties or call any metho
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -41,7 +41,7 @@ You must use an administrator account to call this method.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -42,7 +42,7 @@ Returns an HRESULT value that indicates [WMI status](/windows/win32/wmisdk/wmi-n
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ If **GetExclusions** does not find any files or folders in the file exclusion li
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ This method does not enable UWF if it is disabled; you must explicitly enable UW
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ You must use an administrator account to remove file or folder exclusions, and y
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -39,7 +39,7 @@ You must use an administrator account to remove file or folder exclusions, and y
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -44,7 +44,7 @@ Binding by volume name is considered more reliable than binding by drive letter,
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -37,7 +37,7 @@ Unprotecting the volume does not remove the [UWF_Volume](uwf-volume.md) entry or
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [UWF_Volume](uwf-volume.md)
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -38,6 +38,6 @@ This section describes the WMI provider classes for UWF.
|
||||
| Windows Education | Yes |
|
||||
| Windows IoT Enterprise | Yes |
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [uwfmgr.exe](uwfmgrexe.md)
|
||||
|
@ -209,6 +209,6 @@ The following list contains the UWF WMI provider methods that are not currently
|
||||
- [UWF_Volume.RemoveAllExclusions](uwf-volumeremoveallexclusions.md)
|
||||
- [UWF_Volume.SetBindByDriveLetter](uwf-volumesetbindbydriveletter.md)
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -128,6 +128,6 @@ You can often avoid this issue by using UWF to automatically initiate the shut d
|
||||
|
||||
Windows 10 19H1 and later will automatically restart if the maximum size of the overlay is exceeded.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
- [Unified Write Filter]( index.md)
|
||||
|
@ -20,7 +20,7 @@ UWF uses Windows Event Log to log events, errors and messages.
|
||||
* Error messages are logged in the **Applications and Services Logs\\Microsoft\\Windows\\UnifiedWriteFilter\\Admin** event log.
|
||||
* Informational messages are logged in the **Applications and Services Logs\\Microsoft\\Windows\\UnifiedWriteFilter\\Operational** event log.
|
||||
|
||||
## Related topics
|
||||
## Related articles
|
||||
|
||||
[Unified Write Filter]( index.md)
|
||||
|
||||
|
Reference in New Issue
Block a user