@ -155,29 +155,29 @@ Error creating or updating registry key: **CommercialId** at **HKLM:\SOFTWARE\Mi
>[!NOTE]
>**Additional steps to follow if you receive exit code 33**
>Check the exit code for any of these messages:
>
>- CompatTelRunner.exe exited with last error code: 0x800703F1
>- CompatTelRunner.exe exited with last error code: 0x80070005
>- CompatTelRunner.exe exited with last error code: 0x80080005
> [!NOTE]
> **Additional steps to follow if you receive exit code 33**
>
> Check the exit code for any of these messages:
>
> - CompatTelRunner.exe exited with last error code: 0x800703F1
> - CompatTelRunner.exe exited with last error code: 0x80070005
> - CompatTelRunner.exe exited with last error code: 0x80080005
> 
>
>If the exit code includes any of those messages, then run these commands from an elevated command prompt:
>
>1. Net stop diagtrack
>2. Net stop pcasvc
>3. Net stop dps
>4. Del %windir%\appcompat\programs\amcache.hve
>5. reg delete "HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\AppCompatFlags" /v AmiHivePermissionsCorrect /f
>6. reg add "HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\AppCompatFlags" /v LogFlags /t REG_DWORD /d 4 /f
>7. Net start diagtrack
>8. Net start pcasvc
>9. Net start dps
>
>Then run the Enterprise Config script (RunConfig.bat) again. 
>
>If the script still fails, then send mail to **uasupport@microsoft.com** including log files from the RunConfig.bat script. These log files are stored on the drive that is specified in the RunConfig.bat file. By default this is set to **%SystemDrive%\UADiagnostics**. The log file is named with the format **UA_yyyy_mm_dd_hh_mm_ss_machineID.txt**. There will be some additional logs generated under your **<system drive>\Windows\Temp** directory with the names similar to **AslLog_....txt**. You should send those logs as well.
>
> If the exit code includes any of those messages, then run these commands from an elevated command prompt:
>
> 1. Net stop diagtrack
> 2. Net stop pcasvc
> 3. Net stop dps
> 4. Del %windir%\appcompat\programs\amcache.hve
> 5. reg delete "HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\AppCompatFlags" /v AmiHivePermissionsCorrect /f
> 6. reg add "HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\AppCompatFlags" /v LogFlags /t REG_DWORD /d 4 /f
> 7. Net start diagtrack
> 8. Net start pcasvc
> 9. Net start dps
>
> Then run the Enterprise Config script (RunConfig.bat) again.
>
> If the script still fails, then send mail to <strong>uasupport@microsoft.com</strong> including log files from the RunConfig.bat script. These log files are stored on the drive that is specified in the RunConfig.bat file. By default this is set to **%SystemDrive%\UADiagnostics**. The log file is named with the format **UA_yyyy_mm_dd_hh_mm_ss_machineID.txt**. There will be some additional logs generated under your **<system drive>\Windows\Temp** directory with the names similar to **AslLog_....txt**. You should send those logs as well.