@ -124,7 +124,7 @@ The following table provides information about common errors you might run into
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| CBS_E_CANNOT_UNINSTALL; Package cannot be uninstalled. | Typically this is due component store corruption caused when a component is in a partially installed state. | Repair the component store with the **Dism RestoreHealth** command or manually repair with a payload from the partially installed component. From an elevated command prompt, run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALT*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. | | CBS_E_CANNOT_UNINSTALL; Package cannot be uninstalled. | Typically this is due component store corruption caused when a component is in a partially installed state. | Repair the component store with the **Dism RestoreHealth** command or manually repair with a payload from the partially installed component. From an elevated command prompt, run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. |
## 0x800F0920 ## 0x800F0920
@ -136,13 +136,13 @@ The following table provides information about common errors you might run into
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| CBS_E_SOURCE_MISSING; source for package or file not found, ResolveSource() unsuccessful | Component Store corruption | Repair the component store with the **Dism RestoreHealth** command or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALT*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. | | CBS_E_SOURCE_MISSING; source for package or file not found, ResolveSource() unsuccessful | Component Store corruption | Repair the component store with the **Dism RestoreHealth** command or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. |
## 0x800f0831 ## 0x800f0831
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| CBS_E_STORE_CORRUPTION; CBS store is corrupted. | Corruption in the Windows Component Store. | Repair the component store with **Dism RestoreHealth** or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALT*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. | | CBS_E_STORE_CORRUPTION; CBS store is corrupted. | Corruption in the Windows Component Store. | Repair the component store with **Dism RestoreHealth** or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. |
## 0x80070005 ## 0x80070005
@ -154,7 +154,7 @@ The following table provides information about common errors you might run into
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| ERROR_FILE_CORRUPT; The file or directory is corrupted and unreadable. | Component Store corruption | Repair the component store with **Dism RestoreHealth** or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALT*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device.| | ERROR_FILE_CORRUPT; The file or directory is corrupted and unreadable. | Component Store corruption | Repair the component store with **Dism RestoreHealth** or manually repair with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device.|
## 0x80070003 ## 0x80070003
@ -180,7 +180,7 @@ The following table provides information about common errors you might run into
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| ERROR_SXS_TRANSACTION_CLOSURE_INCOMPLETE; One or more required members of the transaction are not present. | Component Store corruption. | Repair the component store with **Dism RestoreHealth command** or manually repair it with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALT*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. | | ERROR_SXS_TRANSACTION_CLOSURE_INCOMPLETE; One or more required members of the transaction are not present. | Component Store corruption. | Repair the component store with **Dism RestoreHealth command** or manually repair it with the payload from the partially installed component. From an elevated command prompt and run these commands:<br>*DISM /ONLINE /CLEANUP-IMAGE /SCANHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /CHECKHEALTH*<br>*DISM /ONLINE /CLEANUP-IMAGE /RESTOREHEALTH*<br>*Sfc /Scannow*<br> Restart the device. |
## 0x80072EFE ## 0x80072EFE
@ -198,7 +198,7 @@ The following table provides information about common errors you might run into
| Message | Description | Mitigation | | Message | Description | Mitigation |
|---------|-------------|------------| |---------|-------------|------------|
| WININET_E_TIMEOUT; The operation timed out | Unable to scan for updates due to a connectivity issue to Windows Update, Configuration Manager, or WSUS. | This error generally means that the Windows Update Agent was unable to connect to the update servers or your own source, such as WSUS, Configuration Manager, or Microsoft Endpoint Manager. <br> Check with your network team to ensure that the device can reach the update sources. For more info, see [Troubleshoot software update scan failures in Configuration Manager](/mem/configmgr/troubleshoot-software-update-scan-failures). <br> If youre using the public Microsoft update servers, check that your device can access the following Windows Update endpoints: <br> `http://windowsupdate.microsoft.com` <br> https://*.windowsupdate.microsoft.com <br> https://*.windowsupdate.microsoft.com <br> https://*.update.microsoft.com <br> https://*.update.microsoft.com <br> https://*.windowsupdate.com <br> https://download.windowsupdate.com <br> https://download.microsoft.com <br> https://*.download.windowsupdate.com <br> https://wustat.windows.com <br> https://ntservicepack.microsoft.com | | WININET_E_TIMEOUT; The operation timed out | Unable to scan for updates due to a connectivity issue to Windows Update, Configuration Manager, or WSUS. | This error generally means that the Windows Update Agent was unable to connect to the update servers or your own source, such as WSUS, Configuration Manager, or Microsoft Endpoint Manager. <br> Check with your network team to ensure that the device can reach the update sources. For more info, see [Troubleshoot software update scan failures in Configuration Manager](/mem/configmgr/troubleshoot-software-update-scan-failures). <br> If youre using the public Microsoft update servers, check that your device can access the following Windows Update endpoints: <br> `http://windowsupdate.microsoft.com` <br> https://.windowsupdate.microsoft.com <br> https://update.microsoft.com <br> https://*.update.microsoft.com <br> https://windowsupdate.com <br> https://*.windowsupdate.com <br> https://download.windowsupdate.com <br> https://*.download.windowsupdate.com <br> https://download.microsoft.com <br> https://*.download.windowsupdate.com <br> https://wustat.windows.com <br> https://*.wustat.windows.com <br> https://ntservicepack.microsoft.com |
## 0x80240022 ## 0x80240022