mirror of
https://github.com/MicrosoftDocs/windows-itpro-docs.git
synced 2025-06-20 21:03:42 +00:00
Acrolinx suggestions
This commit is contained in:
@ -35,17 +35,17 @@ A Windows Defender Application Control (WDAC) policy logs events locally in Wind
|
||||
| 3089 | Signing information event correlated with either a 3076 or 3077 event. One 3089 event is generated for each signature of a file. Contains the total number of signatures on a file and an index as to which signature it is. Unsigned files will generate a single 3089 event with TotalSignatureCount 0. Correlated in the "System" portion of the event data under "Correlation ActivityID". |
|
||||
| 3099 | Indicates that a policy has been loaded |
|
||||
|
||||
## Microsoft Windows Applocker MSI and Script log event IDs
|
||||
## Microsoft Windows AppLocker MSI and Script log event IDs
|
||||
|
||||
| Event ID | Explanation |
|
||||
|---|----------|
|
||||
| 8028 | Audit script/MSI file generated by Windows LockDown Policy (WLDP) being called by the scripthosts themselves. Note: there is no WDAC enforcement on 3rd party scripthosts. |
|
||||
| 8028 | Audit script/MSI file generated by Windows LockDown Policy (WLDP) being called by the script hosts themselves. Note: there is no WDAC enforcement on third-party script hosts. |
|
||||
| 8029 | Block script/MSI file |
|
||||
| 8038 | Signing information event correlated with either a 8028 or 8029 event. One 8038 event is generated for each signature of a script file. Contains the total number of signatures on a script file and an index as to which signature it is. Unsigned script files will generate a single 8038 event with TotalSignatureCount 0. Correlated in the "System" portion of the event data under "Correlation ActivityID". | |
|
||||
| 8038 | Signing information event correlated with either an 8028 or 8029 event. One 8038 event is generated for each signature of a script file. Contains the total number of signatures on a script file and an index as to which signature it is. Unsigned script files will generate a single 8038 event with TotalSignatureCount 0. Correlated in the "System" portion of the event data under "Correlation ActivityID". | |
|
||||
|
||||
## Optional Intelligent Security Graph (ISG) or Managed Installer (MI) diagnostic events
|
||||
|
||||
If either the ISG or MI is enabled in a WDAC policy, you can optionally choose to enable 3090, 3091, and 3092 events to provide additional diagnostic information.
|
||||
If either the ISG or MI is enabled in a WDAC policy, you can optionally choose to enable 3090, 3091, and 3092 events to provide more diagnostic information.
|
||||
|
||||
| Event ID | Explanation |
|
||||
|---|----------|
|
||||
@ -53,11 +53,11 @@ If either the ISG or MI is enabled in a WDAC policy, you can optionally choose t
|
||||
| 3091 | Audit executable/dll file |
|
||||
| 3092 | Block executable/dll file |
|
||||
|
||||
3090, 3091, and 3092 events are generated based on the status code of whether a binary passed the policy, regardless of what reputation it was given or whether it was allowed by a designated MI. The SmartLocker template which appears in the event should indicate why the binary passed/failed. Only one event is generated per binary pass/fail. If both ISG and MI are disabled, 3090, 3091, and 3092 events will not be generated.
|
||||
3090, 3091, and 3092 events are generated based on the status code of whether a binary passed the policy, regardless of what reputation it was given or whether it was allowed by a designated MI. The SmartLocker template that appears in the event should indicate why the binary passed/failed. Only one event is generated per binary pass/fail. If both ISG and MI are disabled, 3090, 3091, and 3092 events will not be generated.
|
||||
|
||||
### SmartLocker template
|
||||
|
||||
Below are the fields which help to diagnose what a 3090, 3091, or 3092 event indicates.
|
||||
Below are the fields that help to diagnose what a 3090, 3091, or 3092 event indicates.
|
||||
|
||||
| Name | Explanation |
|
||||
|---|----------|
|
||||
@ -76,7 +76,7 @@ In order to enable 3091 audit events and 3092 block events, you must create a Te
|
||||
reg add hklm\system\currentcontrolset\control\ci -v TestFlags -t REG_DWORD -d 0x100
|
||||
```
|
||||
|
||||
In order to enable 3090 allow events as well as 3091 and 3092 events, you must instead create a TestFlags regkey with a value of 0x300. You can do so using the following PowerShell command:
|
||||
To enable 3090 allow events, and 3091 and 3092 events, you must instead create a TestFlags regkey with a value of 0x300. You can do so using the following PowerShell command:
|
||||
|
||||
```powershell
|
||||
reg add hklm\system\currentcontrolset\control\ci -v TestFlags -t REG_DWORD -d 0x300
|
||||
|
Reference in New Issue
Block a user