mirror of
https://github.com/MicrosoftDocs/windows-itpro-docs.git
synced 2025-05-13 05:47:23 +00:00
replaced 'build in insider preview' with actual 1803 name; fixed a couple of style issues
This commit is contained in:
parent
faaafcd461
commit
f15d80c736
@ -42,7 +42,7 @@ In Log Analytics, go to **Settings > Connected sources > Windows telemetry** and
|
||||
|
||||
Even though devices can take 2-3 days after enrollment to show up due to latency in the system, you can now verify the status of your devices with a few hours of running the deployment script as described in [You can now check on the status of your computers within hours of running the deployment script](https://blogs.technet.microsoft.com/upgradeanalytics/2017/05/12/wheres-my-data/) on the Windows Analytics blog.
|
||||
>[!NOTE]
|
||||
> If you generate the status report and get an error message saying "Sorry! We’re not recognizing your Commercial Id," please go to **Settings > Connected sources > Windows telemetry** and unsubscribe, wait a minute and then re-subscribe to Upgrade Readiness. This is a known issue and we are working on a fix.
|
||||
> If you generate the status report and get an error message saying "Sorry! We’re not recognizing your Commercial Id," go to **Settings > Connected sources > Windows telemetry** and unsubscribe, wait a minute and then re-subscribe to Upgrade Readiness.
|
||||
|
||||
If devices are not showing up as expected, find a representative device and follow these steps to run the latest pilot version of the Upgrade Readiness deployment script on it to troubleshoot issues:
|
||||
|
||||
@ -163,7 +163,7 @@ Also, on Windows 10 devices remember that IE site discovery requires data diagno
|
||||
Finally, Upgrade Readiness only collects IE site discovery data on devices that are not yet upgraded to the target operating system version specified in the Upgrade Readiness Overview blade. This is because Upgrade Readiness targets upgrade planning (for devices not yet upgraded).
|
||||
|
||||
### Device Names don't show up on Windows 10 devices
|
||||
Starting with the build currently available in the Windows Insider Program, the device name is no longer collected by default and requires a separate opt-in. For more information, see [Enrolling devices in Windows Analytics](windows-analytics-get-started.md).
|
||||
Starting with Windows 10, version 1803, the device name is no longer collected by default and requires a separate opt-in. For more information, see [Enrolling devices in Windows Analytics](windows-analytics-get-started.md).
|
||||
|
||||
### Disable Upgrade Readiness
|
||||
|
||||
|
@ -44,7 +44,7 @@ To enable data sharing, configure your proxy sever to whitelist the following en
|
||||
|
||||
| **Endpoint** | **Function** |
|
||||
|---------------------------------------------------------|-----------|
|
||||
| `https://v10.events.data.microsoft.com` | Connected User Experience and Diagnostic component endpoint for use with the build of Windows 10 available in the Windows Insider Program|
|
||||
| `https://v10.events.data.microsoft.com` | Connected User Experience and Diagnostic component endpoint for use with Windows 10, version 1803|
|
||||
| `https://v10.vortex-win.data.microsoft.com` | Connected User Experience and Diagnostic component endpoint for Windows 10, version 1709 or earlier |
|
||||
| `https://vortex-win.data.microsoft.com` | Connected User Experience and Diagnostic component endpoint for operating systems older than Windows 10 |
|
||||
| `https://settings-win.data.microsoft.com` | Enables the compatibility update to send data to Microsoft.
|
||||
@ -137,7 +137,7 @@ These policies are under Microsoft\Windows\DataCollection:
|
||||
| CommercialId | In order for your devices to show up in Windows Analytics, they must be configured with your organization’s Commercial ID. |
|
||||
| AllowTelemetry (in Windows 10) | 1 (Basic), 2 (Enhanced) or 3 (Full) diagnostic data. Windows Analytics will work with basic diagnostic data, but more features are available when you use the Enhanced level (for example, Device Health requires Enhanced diagnostic data and Upgrade Readiness only collects app usage and site discovery data on Windows 10 devices with Enhanced diagnostic data). For more information, see [Configure Windows diagnostic data in your organization](https://docs.microsoft.com/windows/configuration/configure-windows-diagnostic-data-in-your-organization). |
|
||||
| LimitEnhancedDiagnosticDataWindowsAnalytics (in Windows 10) | Only applies when AllowTelemetry=2. Limits the Enhanced diagnostic data events sent to Microsoft to just those needed by Windows Analytics. For more information, see [Windows 10, version 1709 enhanced diagnostic data events and fields used by Windows Analytics](https://docs.microsoft.com/windows/configuration/enhanced-diagnostic-data-windows-analytics-events-and-fields).|
|
||||
| AllowDeviceNameInTelemetry (in Windows 10) | In the build currently available in the Windows Insider Program for Windows 10, a separate opt-in is required to enable devices to continue to send the device name. |
|
||||
| AllowDeviceNameInTelemetry (in Windows 10) | In Windows 10, version 1803, a separate opt-in is required to enable devices to continue to send the device name. |
|
||||
| CommercialDataOptIn (in Windows 7 and Windows 8) | 1 is required for Upgrade Readiness, which is the only solution that runs on Windows 7 or Windows 8. |
|
||||
|
||||
|
||||
|
Loading…
x
Reference in New Issue
Block a user