--- title: ADMX_WinInit Policy CSP description: Learn more about the ADMX_WinInit Area in Policy CSP. author: vinaypamnani-msft manager: aaroncz ms.author: vinpa ms.date: 01/09/2023 ms.localizationpriority: medium ms.prod: windows-client ms.technology: itpro-manage ms.topic: reference --- # Policy CSP - ADMX_WinInit > [!TIP] > This CSP contains ADMX-backed policies which require a special SyncML format to enable or disable. You must specify the data type in the SyncML as <Format>chr</Format>. For details, see [Understanding ADMX-backed policies](./understanding-admx-backed-policies.md). > > The payload of the SyncML must be XML-encoded; for this XML encoding, there are a variety of online encoders that you can use. To avoid encoding the payload, you can use CDATA if your MDM supports it. For more information, see [CDATA Sections](http://www.w3.org/TR/REC-xml/#sec-cdata-sect). ## DisableNamedPipeShutdownPolicyDescription | Scope | Editions | Applicable OS | |:--|:--|:--| | :heavy_check_mark: Device
:x: User | :x: Home
:heavy_check_mark: Pro
:heavy_check_mark: Enterprise
:heavy_check_mark: Education
:heavy_check_mark: Windows SE | :heavy_check_mark: Windows 10, version 2004 [10.0.19041.1202] and later
:heavy_check_mark: Windows 10, version 2009 [10.0.19042.1202] and later
:heavy_check_mark: Windows 10, version 21H1 [10.0.19043.1202] and later
:heavy_check_mark: Windows 11, version 21H2 [10.0.22000] and later | ```Device ./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/DisableNamedPipeShutdownPolicyDescription ``` This policy setting controls the legacy remote shutdown interface (named pipe). The named pipe remote shutdown interface is needed in order to shutdown this system from a remote Windows XP or Windows Server 2003 system. - If you enable this policy setting, the system does not create the named pipe remote shutdown interface. - If you disable or do not configure this policy setting, the system creates the named pipe remote shutdown interface. **Description framework properties**: | Property name | Property value | |:--|:--| | Format | chr (string) | | Access Type | Add, Delete, Get, Replace | > [!TIP] > This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to [Enabling a policy](./understanding-admx-backed-policies.md#enabling-a-policy). **ADMX mapping**: | Name | Value | |:--|:--| | Name | DisableNamedPipeShutdownPolicyDescription | | Friendly Name | Turn off legacy remote shutdown interface | | Location | Computer Configuration | | Path | Windows Components > Shutdown Options | | Registry Key Name | Software\Microsoft\Windows\CurrentVersion\Policies\System | | Registry Value Name | DisableShutdownNamedPipe | | ADMX File Name | WinInit.admx | ## Hiberboot | Scope | Editions | Applicable OS | |:--|:--|:--| | :heavy_check_mark: Device
:x: User | :x: Home
:heavy_check_mark: Pro
:heavy_check_mark: Enterprise
:heavy_check_mark: Education
:heavy_check_mark: Windows SE | :heavy_check_mark: Windows 10, version 2004 [10.0.19041.1202] and later
:heavy_check_mark: Windows 10, version 2009 [10.0.19042.1202] and later
:heavy_check_mark: Windows 10, version 21H1 [10.0.19043.1202] and later
:heavy_check_mark: Windows 11, version 21H2 [10.0.22000] and later | ```Device ./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/Hiberboot ``` This policy setting controls the use of fast startup. - If you enable this policy setting, the system requires hibernate to be enabled. - If you disable or do not configure this policy setting, the local setting is used. **Description framework properties**: | Property name | Property value | |:--|:--| | Format | chr (string) | | Access Type | Add, Delete, Get, Replace | > [!TIP] > This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to [Enabling a policy](./understanding-admx-backed-policies.md#enabling-a-policy). **ADMX mapping**: | Name | Value | |:--|:--| | Name | Hiberboot | | Friendly Name | Require use of fast startup | | Location | Computer Configuration | | Path | System > Shutdown | | Registry Key Name | Software\Policies\Microsoft\Windows\System | | Registry Value Name | HiberbootEnabled | | ADMX File Name | WinInit.admx | ## ShutdownTimeoutHungSessionsDescription | Scope | Editions | Applicable OS | |:--|:--|:--| | :heavy_check_mark: Device
:x: User | :x: Home
:heavy_check_mark: Pro
:heavy_check_mark: Enterprise
:heavy_check_mark: Education
:heavy_check_mark: Windows SE | :heavy_check_mark: Windows 10, version 2004 [10.0.19041.1202] and later
:heavy_check_mark: Windows 10, version 2009 [10.0.19042.1202] and later
:heavy_check_mark: Windows 10, version 21H1 [10.0.19043.1202] and later
:heavy_check_mark: Windows 11, version 21H2 [10.0.22000] and later | ```Device ./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/ShutdownTimeoutHungSessionsDescription ``` This policy setting configures the number of minutes the system waits for the hung logon sessions before proceeding with the system shutdown. - If you enable this policy setting, the system waits for the hung logon sessions for the number of minutes specified. - If you disable or do not configure this policy setting, the default timeout value is 3 minutes for workstations and 15 minutes for servers. **Description framework properties**: | Property name | Property value | |:--|:--| | Format | chr (string) | | Access Type | Add, Delete, Get, Replace | > [!TIP] > This is an ADMX-backed policy and requires SyncML format for configuration. For an example of SyncML format, refer to [Enabling a policy](./understanding-admx-backed-policies.md#enabling-a-policy). **ADMX mapping**: | Name | Value | |:--|:--| | Name | ShutdownTimeoutHungSessionsDescription | | Friendly Name | Timeout for hung logon sessions during shutdown | | Location | Computer Configuration | | Path | Windows Components > Shutdown Options | | Registry Key Name | Software\Microsoft\Windows\CurrentVersion\Policies\System | | ADMX File Name | WinInit.admx | ## Related articles [Policy configuration service provider](policy-configuration-service-provider.md)