@ -24,36 +24,34 @@ If you replace your Surface Hub 2S, one of its components, or a related accessor
|
||||
|
||||
Use the following steps to pack your Surface Hub 2S 50" for shipment.
|
||||
|
||||
1. Remove the pen and the camera. Do not pack them with the unit.
|
||||
1. Remove the pen and the camera. Do not pack them with the unit.<br>
|
||||

|
||||
|
||||
2. Remove the drive and the power cable. Do not pack them with the unit. Do not pack the Setup guide with the unit.<br>
|
||||

|
||||
|
||||
3. Unplug all cables, slide the cover sideways, and unscrew the locking screw of the Compute Cartridge.
|
||||
3. Unplug all cables, slide the cover sideways, and unscrew the locking screw of the Compute Cartridge.<br>
|
||||

|
||||
|
||||
4. Slide the Compute Cartridge out of the unit. <br>
|
||||

|
||||
|
||||
5. You will need the Compute Cartridge and a screwdriver.
|
||||
5. You will need the Compute Cartridge and a screwdriver.<br>
|
||||

|
||||
|
||||
6. Remove the cover screw and the cover from the Compute Cartridge, and then remove the solid state drive (SSD).<br>
|
||||

|
||||
|
||||
6. Replace the cover and slide the Compute Cartridge back into the unit.
|
||||
6. Replace the cover and slide the Compute Cartridge back into the unit.<br>
|
||||

|
||||
|
||||
7. Re-fasten the locking screw and slide the cover into place.
|
||||
7. Re-fasten the locking screw and slide the cover into place.<br>
|
||||

|
||||
|
||||
8. Remove any base or mounting hardware. Using two people, place the unit in the base of the shipping container.
|
||||
|
||||
8. Remove any base or mounting hardware. Using two people, place the unit in the base of the shipping container.<br>
|
||||

|
||||
|
||||
9. Replace the cover of the shipping container, and insert the four clips.
|
||||
|
||||
9. Replace the cover of the shipping container, and insert the four clips.<br>
|
||||

|
||||
|
||||
10. Close the four clips.
|
||||
@ -63,34 +61,31 @@ Use the following steps to pack your Surface Hub 2S 50" for shipment.
|
||||
## How to replace and pack your Surface Hub 2S Compute Cartridge
|
||||
|
||||
Use the following steps to remove the Surface Hub 2S Compute Cartridge, pack it for shipment, and install the new Compute Cartridge.<br>
|
||||

|
||||
|
||||

|
||||
|
||||
1. Unplug all cables, slide the cover sideways, and unscrew the locking screw of the Compute Cartridge.
|
||||
1. Unplug all cables, slide the cover sideways, and unscrew the locking screw of the Compute Cartridge.<br>
|
||||

|
||||
|
||||
2. Slide the Compute Cartridge out of the unit.<br>
|
||||

|
||||
|
||||
3. You will need the Compute Cartridge and a screwdriver.
|
||||
3. You will need the Compute Cartridge and a screwdriver.<br>
|
||||

|
||||
|
||||
4. Remove the cover screw and the cover from the Compute Cartridge, and then remove the solid state drive (SSD). When finished, replace the cover.
|
||||
|
||||
4. Remove the cover screw and the cover from the Compute Cartridge, and then remove the solid state drive (SSD). When finished, replace the cover.<br>
|
||||

|
||||
|
||||
5. You will need the packaging fixtures that were used to package your replacement Compute Cartridge.<br>
|
||||

|
||||
|
||||
6. Place the old Compute Cartridge in the packaging fixtures.
|
||||
|
||||
6. Place the old Compute Cartridge in the packaging fixtures. <br>
|
||||

|
||||
|
||||
7. Place the old Compute Cartridge and its packaging into the box that was used for the replacement Compute Cartridge. Reseal the box.<br>
|
||||

|
||||

|
||||
|
||||
8. Slide the replacement Compute Cartridge into the unit.
|
||||
8. Slide the replacement Compute Cartridge into the unit.<br>
|
||||

|
||||
|
||||
9. Fasten the locking screw and slide the cover into place.
|
||||
@ -100,7 +95,7 @@ Use the following steps to remove the Surface Hub 2S Compute Cartridge, pack it
|
||||
|
||||
Use the following steps to remove the Surface Hub 2S camera and install the new camera.
|
||||
|
||||
1. You will need the new camera and the two-millimeter allen wrench
|
||||
1. You will need the new camera and the two-millimeter allen wrench.<br>
|
||||

|
||||
|
||||
2. Unplug the old camera from the unit. If needed, use the allen wrench to adjust the new camera. Plug the new camera into the unit.<br>
|
||||
|