title ms.reviewer manager description keywords ms.prod ms.mktglfcycl ms.pagetype audience author ms.author ms.localizationpriority ms.collection ms.topic
Update Compliance Configuration Script laurawi Downloading and using the Update Compliance Configuration Script update compliance, oms, operations management suite, prerequisites, requirements, updates, upgrades, antivirus, antimalware, signature, log analytics, wdav w10 deploy deploy itpro jaimeo jaimeo medium M365-analytics article

Configuring devices through the Update Compliance Configuration Script

The Update Compliance Configuration Script is the recommended method of configuring devices to send data to Microsoft for use with Update Compliance. The script configures device policies via Group Policy, ensures that required services are running, and more.

You can download the script here. Keep reading to learn how to configure the script and interpret error codes that are output in logs for troubleshooting.

How the script is organized

The script is organized into two folders Pilot and Deployment. Both folders have the same key files: ConfigScript.ps1 and RunConfig.bat. You configure RunConfig.bat according to the directions in the .bat itself, which will then execute ConfigScript.ps1 with the parameters entered to RunConfig.bat.

  • The Pilot folder and its contents are intended to be used on an initial set of single devices in specific environments (main office & satellite office, for example) for testing and troubleshooting prior to broader deployment. This script is configured to collect and output detailed logs for every device it runs on.
  • The Deployment folder is intended to be deployed across an entire device population in a specific environment once devices in that environment have been validated with the Pilot script.

How to use the script

Piloting and Troubleshooting

Important

If you encounter an issue with Update Compliance, the first step should be to run the script in Pilot mode on a device you are encountering issues with, and save these Logs for reference with Support.

Important

The script must be run in the System context. To do this, use the PsExec tool included in the file. For more about PsExec, see PsExec.

When using the script in the context of troubleshooting, use Pilot. Enter RunConfig.bat, and configure it as follows:

  1. Configure logPath to a path where the script will have write access and a place you can easily access. This specifies the output of the log files generated when the script is in Verbose mode.
  2. Configure commercialIDValue to your CommercialID. To get your CommercialID, see Getting your CommercialID.
  3. Run the script. The script must be run in System context.
  4. Examine the Logs output for any issues. If there were issues:
  5. When you no longer have issues, proceed to using the script for more broad deployment with the Deployment folder.

Broad deployment

After verifying on a set of devices in a specific environment that everything is configured correctly, you can proceed to broad deployment.

  1. Configure commercialIDValue in RunConfig.bat to your CommercialID.
  2. Use a management tool like Configuration Manager or Intune to broadly deploy the script to your entire target population.

Script Error Reference

Error Description
27 Not system account.
37 Unexpected exception when collecting logs
1 General unexpected error
6 Invalid CommercialID
48 CommercialID is not a GUID
8 Couldn't create registry key path to setup CommercialID
9 Couldn't write CommercialID at registry key path
53 There are conflicting CommercialID values.
11 Unexpected result when setting up CommercialID.
62 AllowTelemetry registry key is not of the correct type REG_DWORD
63 AllowTelemetry is not set to the appropriate value and it could not be set by the script.
64 AllowTelemetry is not of the correct type REG_DWORD.
99 Device is not Windows 10.
40 Unexpected exception when checking and setting telemetry.
12 CheckVortexConnectivity failed, check Log output for more information.
12 Unexpected failure when running CheckVortexConnectivity.
66 Failed to verify UTC connectivity and recent uploads.
67 Unexpected failure when verifying UTC CSP connectivity of the WMI Bridge.
41 Unable to impersonate logged-on user.
42 Unexpected exception when attempting to impersonate logged-on user.
43 Unexpected exception when attempting to impersonate logged-on user.
16 Reboot is pending on device, restart device and restart script.
17 Unexpected exception in CheckRebootRequired.
44 Error when running CheckDiagTrack service.
45 DiagTrack.dll not found.
50 DiagTrack service not running.
54 Microsoft Account Sign In Assistant (MSA) Service disabled.
55 Failed to create new registry path for SetDeviceNameOptIn of the PowerShell script.
56 Failed to create property for SetDeviceNameOptIn of the PowerShell script at registry path.
57 Failed to update value for SetDeviceNameOptIn of the PowerShell script.
58 Unexpected exception in SetDeviceNameOptIn of the PowerShell script.
59 Failed to delete LastPersistedEventTimeOrFirstBoot property at registry path when attempting to clean up OneSettings.
60 Failed to delete registry key when attempting to clean up OneSettings.
61 Unexpected exception when attempting to clean up OneSettings.
52 Could not find Census.exe
51 Unexpected exception when attempting to run Census.exe
34 Unexpected exception when attempting to check Proxy settings.
30 Unable to disable Enterprise Auth Proxy. This registry value must be 0 for UTC to operate in an authenticated proxy environment.
35 Unexpected exception when checking User Proxy.