3.5 KiB
title, description, author, ms.assetid, ms.pagetype, ms.mktglfcycl, ms.sitesec, ms.prod
title | description | author | ms.assetid | ms.pagetype | ms.mktglfcycl | ms.sitesec | ms.prod |
---|---|---|---|---|---|---|---|
Sequencer Command-Line Parameters | Sequencer Command-Line Parameters | jamiejdt | 28fb875a-c302-4d95-b2e0-8dc0c5dbb0f8 | mdop, appcompat, virtualization | deploy | library | w8 |
Sequencer Command-Line Parameters
You can use the following Application Virtualization (App-V) Sequencer parameters to sequence an application and to upgrade an existing virtual application by using a command line. For more information about sequencing an application by using a command line, see How to Sequence a New Application by Using the Command Line.
Sequencer Command-Line Parameters
/HELP or /?
Displays information about parameters that are available for using a command line to sequence applications.
/INSTALLPACKAGE or /I
Specifies the Windows Installer or a batch file that will be used to install an application so that it can be sequenced.
/INSTALLPATH or /P
Specifies the package root directory for an application.
/OUTPUTFILE or /O
Specifies the path and file name of the SPRJ file that will be generated.
/FULLLOAD or /F
Specifies whether all files will be contained in the primary feature block. If the /FULLLOAD parameter is specified on the command line, all of the associated application data is added to primary feature block. If the /FULLLOAD parameter is not specified on the command line, then none of the associated application data is added to the primary feature block.
/PACKAGENAME or /K
Specifies the package name that will be assigned to the sequenced application.
/BLOCKSIZE
Specifies the SFT file block size that will be used to stream the package to client computers. You can select one of the following values:
-
4 KB
-
16 KB
-
32 KB
-
64 KB
You should consider the size of the SFT file when you specify the block size. A file with a smaller block size takes longer to stream over the network but is less bandwidth-intensive. Files with larger block sizes use more network bandwidth.
/COMPRESSION
Specifies the method for compressing the SFT file that will be streamed to the client.
/MSI or /M
Specifies whether a Windows Installer for the sequenced application should be created.
/DEFAULT
Specifies the default SPRJ file that will be used when creating a virtual application package. This file is used as the .sprj template when the application is sequenced for the first time.
/UPGRADE
Specifies the path and file name of the SPRJ file that will be upgraded.
/DECODEPATH
Specifies the directory on the sequencing computer where the files associated with the sequenced application package are installed. Use one of the following formats when specifying the directory:
-
/decodepath:Q:
-
/decodepath:Q:.
-
/decodepath:”Q:.”
-
/decodepath:”Q:”
Related topics
Application Virtualization Sequencer
Sequencer Command-Line Error Codes